Configuration Byte 35h, APM Status Flags
Default Value = 11h
Bit
Function
7..6
Power Conservation State:
00 = Ready
01 = Standby
10 = Suspend
11 = Off
5,4
Reserved
3
32-bit Connection:
0 = Disconnected, 1 = Connected
2
16-bit Connection
0 = Disconnected, 1 = Connected
1
Real Mode Connection
0 = Disconnected, 1 = Connected
0
Power Management Enable:
0 = Disabled
1 = Enabled
Configuration Byte 36h, ECC POST Test Single Bit Errors
Default Value = 01h
Bit
Function
7
Row 7 Error Detect
6
Row 6 Error Detect
5
Row 5 Error Detect
4
Row 4 Error Detect
3
Row 3 Error Detect
2
Row 2 Error Detect
1
Row 1 Error Detect
0
Row 0 Error Detect
0 = No single bit error detected.
1 = Single bit error detected.
Configuration Byte 37h-3Fh, Power-On Password
These eight locations hold the power-on password.
Configuration Byte 40h, Miscellaneous Disk Data
Configuration Bytes 41h-44h, Hood Removal Time Stamp
These four bytes record the time at which the hood of the system was removed:
Byte 41h, month & day
Byte 42h, year and month
Byte 43h, minutes and seconds
Byte 44h, removal flag and minutes
Compaq Deskpro EN Series o Personal Computers
Net PC and Small Form Factor Models
First Edition - June 1998