IBM T00 Service Manual

7014 series system rack
Table of Contents

Advertisement

ERserver
7014 Series Model T00 and Model T42 System Rack
Service Guide
SA38-0577-05

Advertisement

Table of Contents
loading

Summary of Contents for IBM T00

  • Page 1 ERserver 7014 Series Model T00 and Model T42 System Rack Service Guide SA38-0577-05...
  • Page 3 ERserver 7014 Series Model T00 and Model T42 System Rack Service Guide SA38-0577-05...
  • Page 4 ©International Business Machines Corporation 2000, 2003. All rights reserved. Note to U.S. Government Users - Documentation related to restricted rights - Use, duplication, or disclosure is subject to the restrictions set forth in the GSA ADP Schedule Contract with IBM Corp.
  • Page 5: Table Of Contents

    DC Rack Power Cables ......12 Specifications for 7014 Series Model T00 and Model T42 System Rack Racks ..13 Dimensions .
  • Page 6 Index ........69 7014 Model T00, and Model T42 Service Guide...
  • Page 7: Safety Notices

    Safety Notices A danger notice indicates the presence of a hazard that has the potential of causing death or serious personal injury. v 17 v 21 v 25 A caution notice indicates the presence of a hazard that has the potential of causing moderate or minor personal injury.
  • Page 8: Laser Safety Information

    3B gallium-arsenide laser that is nominally 30 milliwatts at 830 nanometers. The design incorporates a combination of enclosures, electronics, and redundant interlocks such that there is no exposure to laser radiation above a Class 1 level during normal operation, user maintenance, or servicing conditions. 7014 Model T00, and Model T42 Service Guide...
  • Page 9: Data Integrity And Verification

    Data Integrity and Verification IBM computer systems contain mechanisms designed to reduce the possibility of undetected data corruption or loss. This risk, however, cannot be eliminated. Users who experience unplanned outages, system failures, power fluctuations or outages, or component failures must verify the accuracy of operations performed and data saved or transmitted by the system at or near the time of the outage or failure.
  • Page 10 7014 Model T00, and Model T42 Service Guide...
  • Page 11: About This Book

    IBM Eserver pSeries and AIX Information Center at http://publib16.boulder.ibm.com/pseries/index.htm. Click hardware documentation Documentation for the AIX operating system is available at the IBM Eserver pSeries and AIX Information Center at http://publib16.boulder.ibm.com/pseries/index.htm. Click AIX documentation. The AIX Documentation CD contains the base set of publications for the operating system, including system-management and end-user documentation.
  • Page 12 RS/6000 Other company, product, and service names may be trademarks or service marks of others. 7014 Model T00, and Model T42 Service Guide...
  • Page 13: Chapter 1. Reference Information

    Types of Power Distribution Power is distributed to the devices and drawers in the rack by ac power distribution buses or by a dc power distribution panel (Model T00 only). 1 DC Power Distribution Panel 4 AC Power Distribution Bus...
  • Page 14: Ac Rack Information

    (each consuming 1 EIA location) can be mounted horizontally in the bottom rear of a Model T00 rack, and three additional power distribution buses (each consuming 1 EIA location) can be mounted horizontally in the bottom rear of a Model T42 rack. The four vertical mounting slots will be filled first before consuming EIA locations in the rack.
  • Page 15 The following illustration shows the type 6 power distribution bus. 1 Rear View of the Rack 5 Reset Buttons (Two Facing the Front of the Rack) 2 Power Distribution Bus 6 Reset Buttons 3 View of the Power Distribution Bus 7 Outlet for Drawers (Facing the Rack) 4 Outlets for Peripherals (Two Facing...
  • Page 16 7 Circuit Breaker Status Lamp 3 Circuit Breaker 3 8 Front of Power Distribution Bus 4 Power Cord (Plug Configuration May 9 Rear of Power Distribution Bus Vary) 5 Circuit Breaker in Normal Operating Position 7014 Model T00, and Model T42 Service Guide...
  • Page 17 For type 6 buses, the ac power is not switched prior to the individual power outlet circuit breakers. 1a Reset Circuit Breaker 1 7a Reset Circuit Breaker 7 2a Reset Circuit Breaker 2 8a Reset Circuit Breaker 8 3a Reset Circuit Breaker 3 9 AC Outlets 4a Reset Circuit Breaker 4 10 AC Outlets Used to Power on...
  • Page 18 1a Circuit Breaker 1 (15 Amp) 4 AC Power Input 2a Circuit Breaker 2 (15 Amp) 5 AC Outlets (quantity 9) 3a Circuit Breaker 3 (15 Amp) Note: The maximum total amperes is 24 amps. 7014 Model T00, and Model T42 Service Guide...
  • Page 19 The following illustration shows the type 7 three phase power distribution bus. Type 7 Three Phase Power Distribution Bus Phase 1 Outlets (11) Power Phase 2 Input Circuit Phase 3 Breaker 1 Neutral Circuit Breaker 2 Circuit Breaker 3 Circuit Breaker 4 Circuit Breaker 5...
  • Page 20 1f Circuit Breaker 6 (20 Amp) 1b Circuit Breaker 2 (20 Amp) 2 AC Power Input 1c Circuit Breaker 3 (20 Amp) J1–J12 AC Outlets 1d Circuit Breaker 4 (20 Amp) 1e Circuit Breaker 5 (20 Amp) 7014 Model T00, and Model T42 Service Guide...
  • Page 21: Ac Power Distribution Bus Illustration

    An uninterruptible power source (UPS) can be installed in the rack that contains an ac power distribution bus. The uninterruptible power source powers one drawer or device. The uninterruptible power source contains a power plug (input) and one power outlet (output). IBM offers several UPSs as type 9910 in the pSeries configurator.
  • Page 22: Dc Rack Information

    7 Bezel Mounting Screws 3 Bus Bar Shield (Insulation) 8 Circuit Breaker Switches 4 Terminal Block (Both Sides of the 9 Circuit Breaker Position Labels Rear Cover) 5 Covers for Empty Circuit Breaker Positions 7014 Model T00, and Model T42 Service Guide...
  • Page 23: Dc Rack Configuration

    DC Rack Configuration The dc rack must be connected to an external -48 V dc power source. The -48 V dc power source must be electrically isolated from the ac power source. In addition, the -48 V dc source must be grounded. The dc rack can be connected to one or two -48 V dc power source to provide redundant power backup.
  • Page 24: Dc Rack Power Cables

    Power cables and ground cables must be a minimum of 6 AWG stranded copper (or equivalent) for lengths up to 50 feet from the power source. v All connectors must be the copper crimp type (compression). Connector metal must be compatible with the cable metal. 7014 Model T00, and Model T42 Service Guide...
  • Page 25: Specifications For 7014 Series Model T00 And Model T42 System Rack Racks

    – T00 and T42 with Rear Door only: 1042 mm (41 in) – T00 with Rear and Front Door: 1098 mm (43.3 in) - Feature 6097 and Feature 6068 – T00 with Rear and Front Door: 1147 mm (45.2 in) - Feature 6088 –...
  • Page 26: Service Inspection Guide

    10 Threaded Hole (Used to secure the rack to mounting plate.) 5 Spacer 11 Anchor Bolt Hole 6 Jam Nut 12 Traced Pattern (Pattern to be traced onto the floor using the mounting plate as a template) 7014 Model T00, and Model T42 Service Guide...
  • Page 27 2. If the rack is not bolted down, ensure that the stabilizers are firmly attached to both the bottom front and bottom rear of the rack. CAUTION: The stabilizer must be firmly attached to the bottom front of the rack to prevent the rack from turning over when the drawers are pulled out of the rack.
  • Page 28 15. Perform the power-on procedure for the power distribution system installed in your rack. See “Power-On Procedure with the AC Power Distribution Bus” on page 25 and “Power-On Procedure with the DC Power Distribution Panel” on page 27. 7014 Model T00, and Model T42 Service Guide...
  • Page 29: Chapter 2. Maintenance Analysis Procedures (Maps)

    Chapter 2. Maintenance Analysis Procedures (MAPs) This chapter provides diagnostic steps for detecting power problems in the rack. Use these power MAPs only if you are directed here from a MAP step in the Diagnostic Information for Multiple Bus Systems. If your rack has a power distribution panel, follow the instructions for “MAP 1520: DC Power Distribution Panel - Power MAP.”...
  • Page 30 Replace the device power supply. Go to “Step 1520-8” on page 19. Go to ″MAP 0410: Repair Checkout″ in the Diagnostic Information for Multiple Bus Systems. CAUTION: Energy hazard, remove power before servicing. Disconnect two power supply cords. 7014 Model T00, and Model T42 Service Guide...
  • Page 31 Step 1520-8 Is there power to the drawer? Go to “Step 1520-9.” Go to ″MAP 0410: Repair Checkout″ in the Diagnostic Information for Multiple Bus Systems. Step 1520-9 Set the circuit breaker to the off position, and replace the power cable between the circuit breaker and the device.
  • Page 32 Replace the power supply. Then go to ″MAP 0410: Repair Checkout″ in the Diagnostic Information for Multiple Bus Systems. Replace the cable. Then go to ″MAP 0410: Repair Checkout″ in the Diagnostic Information for Multiple Bus Systems. 7014 Model T00, and Model T42 Service Guide...
  • Page 33: Map 1522: Ac Power Distribution Bus - Power Map

    MAP 1522: AC Power Distribution Bus - Power MAP Purpose of This MAP This procedure is used to locate power problems in the power distribution bus. If a problem is detected, this procedure will help you isolate the failing field replaceable unit (FRU). If the rack contains more than one power distribution bus, use this MAP to test the power distribution bus that is connected to the failing drawer.
  • Page 34 Did the drawer power reset circuit breaker on the power distribution bus go to the Off position (pop out)? Go to “Step 1522-7” on page 23. Go to “Step 1522-9” on page 23. 7014 Model T00, and Model T42 Service Guide...
  • Page 35 Step 1522-7 Plug the drawer power cable into another outlet on the power distribution bus. 2. Turn on power to the drawer. Did the drawer power light come on and stay on? Go to “Step 1522-8.” The first outlet is defective. Use the second outlet, or exchange the power distribution bus, and then go to “Step 1522-10.”...
  • Page 36 7014 Model T00, and Model T42 Service Guide...
  • Page 37: Chapter 3. Removal And Replacement Procedures

    Chapter 3. Removal and Replacement Procedures This chapter contains information about powering the rack on and off, and removing and replacing components. Use the correct power-on and power-off procedure for the type of power distribution used in your rack. Safety Notices This section contains safety notices that apply to all the procedures in this chapter.
  • Page 38 3. Follow the power-on procedures for the drawers installed in the rack. For more information, refer to the service guide for the drawers installed in the rack. 4. Close the rear door of the rack. 7014 Model T00, and Model T42 Service Guide...
  • Page 39: Power-Off Procedure With The Ac Power Distribution Bus

    Power-Off Procedure with the AC Power Distribution Bus This section covers the ac power-off procedure. 1. Be sure the operating system is shut down. See “Operating System Shutdown” on page 25. 2. Power off each of the drawers installed in the rack. For more information, refer to the service guide for the drawers installed in the rack.
  • Page 40 4. Turn on power to all external devices attached to the system unit. For more information, refer to the service guide. 5. Set all the circuit breakers to the on position (up). 6. Turn on power to all of the devices and drawers connected to the dc power distribution panel. 7014 Model T00, and Model T42 Service Guide...
  • Page 41: Power-Off Procedure With The Dc Power Distribution Panel

    Power-Off Procedure with the DC Power Distribution Panel This section covers the power-off procedure for the dc rack. 1. Be sure the operating system is shut down. See “Operating System Shutdown” on page 25. 2. Turn off power to all devices and drawers in the rack. For more information, refer to the service guide. 3.
  • Page 42: Removal

    5. Unplug the power cables from the other side of the bus. Remove the ac power distribution bus from the rack. 7014 Model T00, and Model T42 Service Guide...
  • Page 43: Replacement

    6. On 9188 or 7188 ac power distribution buses only, remove the top and bottom L-bracket on the PDU via the two screws per bracket. Replacement This section covers the replacement for the ac power distribution bus. 1. On 9188 or 7188 ac power distribution buses only, install the top and bottom L-bracket on the PDU via the two screws per bracket.
  • Page 44 3 A -48 V dc (-) Power Cable 8 B Return (-) Bus Bar 4 A Return (-) Bus Bar 9 B -48 V dc (-) Bus Bar 5 A Return (-) Power Cable 7014 Model T00, and Model T42 Service Guide...
  • Page 45 11. Remove the four mounting screws that attach the dc power distribution panel to the top of the rack, and remove the panel. 1 Ground Wire with Connector 4 Ground Wire Connector 2 Mounting Screw (quantity 4) 5 Mounting Screw (This screw secures both the Power Distribution Panel and the Ground Wire.) 3 Power Distribution Panel...
  • Page 46: Replacement

    9 B -48 V dc (-) Bus Bar 5 A Return (-) Power Cable 8. Replace the -48 V dc bus bar shield (insulation). 9. Replace the top cover of the dc power distribution panel. 7014 Model T00, and Model T42 Service Guide...
  • Page 47 10. If necessary, replace the cable channel cover. 1 Mounting Screw (quantity 4) 4 Shield 2 Cable Channel Cover 5 Power Distribution Panel (PDP) 3 Mounting Screw (quantity 6) 6 Front of Rack 11. Have the customer turn on the -48 V dc power source. 12.
  • Page 48: Removal And Replacement Of The -48 V Dc Circuit Breaker

    7 Bezel Mounting Screws 3 Bus Bar Shield (Insulation) 8 Circuit Breaker Switches 4 Terminal Block (Both Sides of the 9 Circuit Breaker Position Labels Rear Cover) 5 Covers for Empty Circuit Breaker Positions 7014 Model T00, and Model T42 Service Guide...
  • Page 49 7. Using a multimeter, verify that no voltage exists between the -48 V dc bus bars and the -48 V dc return bus bars, A and B sides. 8. Record the locations of all cables or wires connected to the three connector pins on the circuit breaker that is being removed.
  • Page 50: Replacement

    8. Have the customer restore power to the dc power distribution panel. 9. Be sure all circuit breakers are set to on. 10. Follow the steps in “Power-On Procedure with the DC Power Distribution Panel” on page 27. 7014 Model T00, and Model T42 Service Guide...
  • Page 51: Removal And Replacement Of The Front Or Rear Door

    Removal and Replacement of the Front or Rear Door It is possible that inspection or service procedures for certain drawers might require removing the front or rear door for better access. If this is necessary, follow these instructions. Removal This section covers the removal procedure for the front or rear door. Open the door of the rack.
  • Page 52: Relocating Rack(S)

    Relocating Rack(s) To relocate a rack refer to step-by-step instructions described in the 7014 Series Model T00 and Model T42 System Rack Installation Guide, order number SA38-0614. 7014 Model T00, and Model T42 Service Guide...
  • Page 53: Chapter 4. Parts Information

    Chapter 4. Parts Information This chapter contains detailed drawings, field replaceable unit (FRU) part numbers, and part descriptions for a 7014 Series Model T00 and T42 rack. Covers Table 1. Frames, Side Panels, and Top Cover Index Number FRU Part Number...
  • Page 54 31L8594 Screw Screw Table 4. Mounting Hardware for Front Door Index Number FRU Part Number Units Per Assembly Description 21P4042 Hinge (100 mm) 21P4043 Latch plate (100 mm) 31L8594 Screw 31L7540 Screw 7014 Model T00, and Model T42 Service Guide...
  • Page 55 T00, with foam, round, white (20 mm) 11P0723 T42, with foam, round, white (20 mm) 21P4468 T00, with foam, hex, black (20 mm) 21P4467 T42, with foam, hex, black (20 mm) Table 6. Mounting Hardware for Rear Door Index Number...
  • Page 56: Model T42 Top Frame

    Top Cable Access Cover (White) 31L7536 Top Frame Side Panel (Black) 05N6805 Top Frame Side Panel (White) 05N6478 Lower Side Panel (Black) 05N6477 Lower Side Panel (White) 11P0313 Rack Frame (Black) 11P0314 Rack Frame (White) 7014 Model T00, and Model T42 Service Guide...
  • Page 57: Earthquake Brace

    Earthquake Brace Index Number FRU Part Number Units Per Assembly Description 05N4697 Earthquake brace kit Hinge Spacer Screw 76X4687 Bolt * Shown for reference only. Chapter 4. Parts Information...
  • Page 58: Blank Fillers

    As needed 12J4073 As needed 3U Filler screw (black) 74F1823 2/Item3 M5 Nut clip 74F1823 4/Item4 M5 Nut clip 1624779 2/Item3 M5 X 14 Hex flange 1624779 4/Item4 M5 X 14 Hex flange 7014 Model T00, and Model T42 Service Guide...
  • Page 59: Power Distribution Bus

    Power Distribution Bus Index Number FRU Part Number Units Per Assembly Description 00P2200 Type 6 power distribution panel (1 phase U.S.) 00P2201 Type 6 power distribution panel (2/3 phase) 00P2202 Type 6 power distribution panel (3 phase) 00P22023 Type 6 power distribution panel (1 Phase World Trade) 00P3663...
  • Page 60: Stabilizers

    Note: For information on type 6 and type 7 power distribution buses, see “AC Power Distribution Bus” on page 2. Stabilizers Index Number FRU Part Number Units Per Assembly Description 31L8305 Front stabilizer kit (black) 31L8306 Front stabilizer kit (white) 7014 Model T00, and Model T42 Service Guide...
  • Page 61: Power Distribution Panel Assembly

    Index Number FRU Part Number Units Per Assembly Description 44P1850 Rear stabilizer kit (black) 44P1851 Rear stabilizer kit (white) Screw, M8X25 button head (shipped as part of stabilizer kit) * Shown for reference only. Screws are included in the stabilizer kits. Power Distribution Panel Assembly Index Number FRU Part Number...
  • Page 62: Power Distribution Panel Interior

    * Shown for reference only. Power Distribution Panel Interior Index Number FRU Part Number Units Per Assembly Description 00P1793 varies 20 Amp cable 11K0402 varies 30 Amp cable 11K0401 varies 50 Amp cable 7014 Model T00, and Model T42 Service Guide...
  • Page 63: Leveling Feet

    Leveling Feet Index Number FRU Part Number Units Per Assembly Description Jam nut Leveling Feet 31L8313 Wrench * Shown for reference only. Chapter 4. Parts Information...
  • Page 64: Model T42 Brace

    Model T42 Brace Rear of Rack Index Number FRU Part Number Units Per Assembly Description 12K0489 Brace Bolt * Shown for reference only. 7014 Model T00, and Model T42 Service Guide...
  • Page 65: Rack Beacon Assembly

    Rack Beacon Assembly Index Number FRU Part Number Units Per Assembly Description 53P1775 Cover 53P1774 Power Supply 53P2231 Junction Box Assembly 53P1776 53P3997 Card Assembly 53P1777 Lens 53P2236 Cable Not Shown 53P2237 Varies USB Cable Not Shown 53P2854 USB Cable Chapter 4.
  • Page 66: Model T42 Kits (For Reference Only)

    Attachment (black T00 only) 05N4658 Attachment (white T00 only) 11P0423 Attachment (white T42 only) 11P0424 Attachment (white only) 03N3281 Top cable tray (white) 03N3726 Top cable tray (end cover) 11K0928 Rack ground kit 7014 Model T00, and Model T42 Service Guide...
  • Page 67: Power Cords

    Power Cords Index Number FRU Part Number Units Per Assembly Country or Region 11F0113 U.S. Standard, type 12 plug, L6-30P twist-lock connector, 14 foot cord 30 A, single phase U.S.A., Canada Anguilla, Antigua, Cape Verde Islands, Cayman Islands, French Polynesia, Honduras, Montserrat, St.
  • Page 68 3-pin waterproof connector, 6 foot cord Type 40 plug, R&S 3750 30 A, single phase Chicago, Illinois, U.S.A. 11F0106 30 A, single phase, PDL connector Wilco WP, type PDL plug, 14 foot cord Australia 7014 Model T00, and Model T42 Service Guide...
  • Page 69 Index Number FRU Part Number Units Per Assembly Country or Region 11F0107 30 A, single phase, PDL connector Wilco WP, type PDL plug, 14 foot cord Australia Chapter 4. Parts Information...
  • Page 70 Vincent, Sao Thome Island, Saudi Arabia, Senegal, Serbia, Sierra Leone, Slovakia, Slovenia, Somalia, South Yemen, Spain, Sudan, Swaziland, Syria, Tanzania, Togo, Tunisia, Uganda, Ukraine, United Arab Emirates, United Kingdom, Vietnam, Western Samoa, Zaire, Zambia, Zimbabwe 7014 Model T00, and Model T42 Service Guide...
  • Page 71 Index Number FRU Part Number Units Per Assembly Country or Region 88G4763 32 A, 2 of 3 phase, five pin connector IEC 309, type 46 connector (3 power + neutral + ground), 14 foot cord Austria, Czech Republic, Denmark, Estonia, Finland, Israel, Latvia, Liechtenstein, Lithuania, Netherlands, Norway, Pakistan, Portugal,...
  • Page 72 7014 Model T00, and Model T42 Service Guide...
  • Page 73: Appendix A. Environmental Notices

    Before this unit is disposed of, these materials must be removed and recycled or discarded according to applicable regulations. IBM offers product-return programs in several countries. For country specific instructions refer to the following web site: http://www.ibm.com/ibm/environment/products/prp.phtml This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery.
  • Page 74 Batterie muss wieder verwertet oder als Sondermüll entsorgt werden. Es ist möglich, dass es in Ihrer Nähe keine Wiederverwertungsanlage gibt. Weitere Informationen zur Entsorgung von Batterien erhalten Sie von Ihrem örtlichen Müllentsorgungsunternehmen. 7014 Model T00, and Model T42 Service Guide...
  • Page 75 Questo prodotto potrebbe contenere una batteria al piombo, al nichel-cadmio, all ’idruro di nichel, al litio o agli ioni di litio. Consultare il manuale utente o il manuale di assistenza per informazioni specifiche sulla batteria. La batteria deve essere appropriatamente riciclata o smaltita. Il servizio per il riciclaggio potrebbero non essere disponibile nella vostra zona.
  • Page 76 Batteriet måste lämnas till återvinning eller kastas på ett miljösäkert sätt. Det kanske inte finns några återvinningsmöjligheter där du bor . När det gäller omhändertagande av batterier ber vi att få hänvisa till myndigheternas anvisningar i respektive land. 7014 Model T00, and Model T42 Service Guide...
  • Page 77: Environmental Design

    In the United States, IBM has established a collection process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and other battery packs from IBM Equipment. For information on proper disposal of these batteries, please contact IBM at 1-800-426-4333.
  • Page 78: Acoustical Noise Emissions

    There is no declared acoustical noise emission for the system rack. The declared acoustical noise emissions can be found in the service guides for each of the system drawers installed into the 7014 Series Model T00 and Model T42 System Rack. 7014 Model T00, and Model T42 Service Guide...
  • Page 79: Appendix B. Notices

    Appendix B. Notices This information was developed for products and services offered in the U.S.A. The manufacturer may not offer the products, services, or features discussed in this document in other countries. Consult the manufacturer’s representative for information on the products and services currently available in your area.
  • Page 80 7014 Model T00, and Model T42 Service Guide...
  • Page 81: Index

    Index Special characters -48 v dc circuit breaker removal and replacement 36 information, accessing ix about this book ix kits 54 ac power distribution bus 2 ac power distribution bus illustration 9 ac power distribution bus power-off procedure 27 ac power distribution bus power-on procedure 25 laser vi ac power distribution bus removal and replacement 29 laser compliance statement vi...
  • Page 82 39 removal and replacement procedures 25 safety notices v laser compliance statement vi service inspection guide 14 stabilizers 48 trademarks ix types of power distribution 1 7014 Model T00, and Model T42 Service Guide...
  • Page 83 Thank you for your responses. May we contact you? h Yes h No When you send comments to IBM, you grant IBM a nonexclusive right to use or distribute your comments in any way it believes appropriate without incurring any obligation to you. Name...
  • Page 84 Readers’ Comments — We’d Like to Hear from You Cut or Fold Along Line SA38-0577-05 Fold and Tape Please do not staple Fold and Tape _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ NO POSTAGE NECESSARY IF MAILED IN THE...
  • Page 86 Printed in USA November 2003 SA38-0577-05...

This manual is also suitable for:

T427014 t007014 t42

Table of Contents