Hoveround-MPV5ManualRevM
If a fault occurs, you can find out what has happened by counting
the number of bars on the battery gauge that are flashing.
VSI Controller
1 bar:
2 bars:
3 bars:
4 bars:
5 bars:
6 bars:
7 bars:
8 bars:
9 bars:
10 bars:
10 bars Rapid Flash: Powered up when joystick deflected.
10 bars, Three Second Blink: Control is in sleep mode.
Speed Bars Cycling: Controller locked.
Speed Bars Flashing: Power seat lift is inhibiting drive.
D82008753M 10/13
1/17/14
10:37 AM
Page 57
Low battery or a bad connection.
Try recharging the battery.
Bad connection to left motor.
Short circuit, left motor to battery.
Bad connection to right motor.
Short circuit, right motor to battery.
Check if battery charger is still connected
to controller or controller fault.
Joystick fault.
Controller fault.
Problem with brake circuit. Check that manual brake
release levers are in the drive position and power seat
lift is lowered (if equipped).
An excessive voltage to the control system. This is
usually caused by a poor battery connection.
Restart with joystick in neutral.
Press OFF/ON twice to restart.
Lower the seat.
Chapter 9