Indoor Unit

Automatic Operation Switch
• Press for < 5s to run Automatic Operation.
(Used when the remote control cannot be used.)
• Press continuously for 5s and < 8s to run
Forced Cooling Operation.
• Press continuously for 8s and < 11s to
run Forced Heating Operation.
• Press continuously for 11s and < 16s to
change different remote controlling
setting (A↔B Mode).
• Press continuously for 16s or < 21s to
switch OFF / ON Remote Control
Receiving Sound or H14 Abnormality
Detection Mode.
Operation Indication Lamps (LED)
POWER
MONITOR
(Green) ............ Lights up in Ionizer
POWER
TIMER
QUIET
POWERFUL
(Green) ...... Lights up during
compressor operation.
Mode Operation.
(Green) ...... Lights up in
operation, blinks in
Automatic Operation
Mode judging and Hot
Start operation.
(Orange) .... Lights up in Timer
Setting.
Blinks in Self
Diagnosis Control.
(Orange) .... Lights up in Quiet
Mode Operation.
(Orange) ... Lights up when
Powerful Mode is
selected.
Five Operation Modes
• Automatic, Heating, Cooling, Soft Dry
and Fan Operation.
Automatic and 5 Manual Indoor
Fan Speeds
Automatic and 5 Manual Vertical
Airflow Directions
Automatic and 5 Manual Horizontal
Airflow Directions
Powerful Mode
• For quick cooling or heating.
Quiet Mode
• To provide extra quiet operation.
Ionizer Control
• Ionizer control for generate negative ion
in discharge air.
Delay ON Timer and OFF Timer
Automatic Restart Control
• Operation is restarted after power failure
at previous setting mode.
Microcomputer-controlled Room
Temperature Control