Model Information - LG AH-W096A0 Service Manual

Lg thermav system ah series air conditioners
Table of Contents

Advertisement

1. Model Information

With advanced inverter technology,
hot water generation. By Interfacing to various accessories user can customize the range of the application.
In this chapter, general information of
installation, read this chapter carefully and find helpful information on installation.
1. Model Information
Model number nomenclature
A
H
W
Model name and related information
Model Name
Set
Indoor Unit Outdoor Unit
AH-W096A0
AHNW096A0 AHUW096A0
AH-W126A0
AHNW126A0 AHUW126A0
AH-W146A0
AHNW146A0 AHUW146A0
AH-W166A0
AHNW166A0 AHUW166A0
*1 : tested under Eurovent Heating condition (water temperature 30°C
*2 : tested under Eurovent Cooling condition (water temperature 23°C ¡ 18°C at outdoor ambient temperature 35°C / 24°C)
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
is suitable for applications like under floor heating, under floor cooling, and
is presented to identify the installation procedure. Before beginning
0
9
6
A
0
Heating
(kW) *
9
12
14
16
Series Number
Chassis Name
Electrical ratings
6 : 1 phase 220~240V AC 50Hz
Heating Capacity (kW)
09 : 9kW
12 : 12kW
14 : 14kW
Model Type
W : Inverter Heat Pump
H : Heat Pump
Classification
N : Indoor Unit
U : Outdoor Unit
Air-to-Water Heat Pump for R410A
Capacity
Built-In Electric
Cooling
Heater(kW)
1
(kW) *
2
8.6
4 (2+2)
14
14
6 (3+3)
14
¡ 35°C at outdoor ambient temperature 7°C / 6°C)
- 9 -
Model Information
8 : 3 phase 380~415V AC 50Hz
16 : 16kW
— : Set
Power Source
1 x 220~240V
x 50Hz
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents