LG AH-W096A0 Service Manual page 70

Lg thermav system ah series air conditioners
Table of Contents

Advertisement

Trouble Shooting
Display
Title
code
DC Link
23
Low voltage.
DC Link
28
High voltage
Check Flow Chart
Check the wire
connection.(U,V,W)
Is it normal ?
Yes
Is it normal ?
Yes
Is it normal ?
Yes
Check the input power
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Cause of error
• 1ph : DC link volt. is
140Vdc .
• 3ph : DC link volt. is
250Vdc .
• 1ph : DC link volt. is
140Vdc .
• 3ph : DC link volt. is
250Vdc .
❊ Check DC link voltage
❊ Check TRANS1
No
Correct
connection
No
Change
Compressor
❊ Dc link voltage table
No
Change
Compressor
1 Phase
3 Phase
- 70 -
Check point & Normal condition
• Check the power source.
• Check the components.
• Check the power source.
• Check the components.
CN_TRANS 1
Model
Type
Non operating
AUUW126C
PSC
DC300V ¡¾ 10%
AUUW186C
PSC
DC300V ¡¾ 10%
AUUW246D
PFC
DC300V ¡¾ 10%
AUUW306D
PFC
DC300V ¡¾ 10%
AUUW366D
PFC
DC300V ¡¾ 10%
AUUW426D
PFC
DC300V ¡¾ 10%
AUUW486D
PFC
DC300V ¡¾ 10%
AUUW606D
PFC
DC300V ¡¾ 10%
AUUW368D
PSC
DC540V ¡¾ 10%
AUUW428D
PFC
DC540V ¡¾ 10%
AUUW488D
PFC
DC540V ¡¾ 10%
AUUW608D
PFC
DC540V ¡¾ 10%
V
DC Link Voltage
Operating
DC280V ¡¾ 10%
DC280V ¡¾ 10%
DC380V ¡¾ 10%
DC380V ¡¾ 10%
DC380V ¡¾ 10%
DC380V ¡¾ 10%
DC380V ¡¾ 10%
DC380V ¡¾ 10%
DC500V ¡¾ 10%
DC680V ¡¾ 10%
DC680V ¡¾ 10%
DC680V ¡¾ 10%
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents