6. Outdoor Fan Control
6.1 Function
Working of outdoor fan are different in different models.
Some models are single fan, some are two fan type.
6.2 Operating process
Control logic of outdoor fan depends on outdoor temperature.
1. DC motor fan control
Model
AHUW166A0
Outdoor Temperature
41~45°C
38~41°C
28~38°C
24~28°C
18~24°C
14~18°C
9~14°C
2~9°C
-3~2°C
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Base Step
670
Cooling Step
Outdoor Temperature
Base Step+2
Base Step+1
Base Step
Base Step-2
Base Step-4
Base Step-6
Base Step-7
Base Step-8
Base Step-9
- 36 -
RPM
Max Step
700
22~26°C
18~22°C
14~18°C
10~14°C
4~10°C
0~4°C
-4~0°C
-8~-4°C
-
Control logic
Min Step
200
Heating Step
Base Step-4
Base Step-3
Base Step-2
Base Step-1
Base Step
Base Step+1
Base Step+2
Base Step+3
-
LGE Internal Use Only