Advertisement

Air Bleeding by Priming Pump
In case air is not bled due to malfunction of the fuel sole-
noid pump, operating the priming pump only can bleed air.
1. Check that fuel cock (3) on the bottom of the fuel tank is
opened.
2. Loosen air bleed plug (1) on the fuel main filter.
3. Supply fuel by reciprocating priming pump (6). After no
air bubbles are spouted through air bleed plug (1), tight-
en air bleed plug (1).
4. After tightening air bleed plug (1), reciprocate priming
pump (6) approx. 150 strokes.
5. Wipe off any spilled fuel.
6. Start the engine. Check that no fuel leaks are present. If
the engine does not start, repeat the above procedures
from step 1.
Wrench size: 10 mm
Air Bleeding by Cranking
Bleed air from the fuel system after changing the common
rail.
Bleeding Procedures
1. Bleed air until the engine supply pump entrance enough
according to the above-mentioned procedures.
2. Operate starter motor for long cranking within 20 sec-
onds. If engine falls to start, return key switch to OFF. Wait
more than about 60 seconds, then try again.