ROM version indication

Exiting the Self-diagnostic mode

Press the CHARACTER button on the RCP-750/751/920/
921 remote control panel or the RM-B750 repeatedly to
display the ROM version indication page, then press the
CHARACTER button again.

When an error occurs

The error message is displayed on the monitor. In such a
case, the self-diagnostics page corresponding to the board
where the error has occurred appears by pressing the
CHARACTER button.
When you keep pressing the CHARACTER button, pages
are automatically turned to a screen with no characters
(character OFF screen).

Specifications

General

Power consumption
100 - 240 V AC, 50/60 Hz, maximum
1.8 A
Peak inrush current
(1) Power ON, current probe method:
50 A (240 V)
(2) Hot switching inrush current,
measured in accordance with European
standard EN55103-1: 10 A (230 V)
1)
50 to 700 m (Fujikura φ8.5 mm)
Cable length
75 to 1,050 m (BELDEN 9232
φ13.2 mm)
100 to 1,400 m (Fujikura φ14.5 mm)
Operating temperature
–10 °C to +40 °C (14 °F to 104 °F)
Dimensions
200 × 124 × 365 mm (8 × 5 × 14
(w / h / d) not including projecting
parts
Mass
Approx. 5.5 kg (12 lb 2 oz)
1)
Teleprompter signals are only compatible with the following cable
lengths.
• 50 to 500 m (Fujikura φ8.5 mm)
• 75 to 750 m (BELDEN 9232 φ13.2 mm)
• 100 to 1,000 m (Fujikura φ14.5 mm)

Input signals

REFERENCE
BNC type (loopthrough)
VBS/BS, 1.0 Vp-p, 75 ohms
2)
RET 1/2
BNC type (1 each, loopthrough)
VBS, 1.0 Vp-p, 75 ohms
2)
PROMPTER
BNC type (loopthrough)
1.0 Vp-p, 75 ohms
3)
SDI RET 3/4
BNC type (1 each)
VBS, 1.0 Vp-p, 75 ohms (terminated
internally)
SDI format, 270 Mbps, SMPTE 259M
2)
The same signal is input to the RET-2 connectors and the
PROMPTER connector.
3)
The signal selection (SDI or VBS) input to the SDI-RET 3/4
connectors is switchable.

Output signals

4)
VBS/SDI 1/2/3
BNC type (1 each)
VBS, 1.0 Vp-p, 75 ohms
SDI format, 270 Mbps, SMPTE 259M