Dynamic fiber conversion system

Advertisement

Quick Links

Description:

The
DFCS
converters are members of the modular
family. The following models are described:
- 100Tx-2Fx: 100Base-Tx UTP to dual 100Base-Fx dual fiber
- 100Tx-2Tx: 100Base - Tx UTP to dual 100Base-Tx UTP
Dynamic Fiber Conversion System
DFCS
The
100Tx-2Fx & 100Tx-2Tx User Manual
for use in networks that require fiber or copper link
redundancy. During normal operations Port A is the active
primary and Port B is the backup secondary. When loss of
link on Port A is detected, the module automatically switches
to transmitting on Port B. With a switch over time
Connector
Distances
ST
SC
of less than 100 microseconds, these modules provide
Type
the rapid response time required for ultra critical
applications. Note: After the link is switched, there will be
MM
5km
LMC3044C
LMC3047C
a 5 second delay before that link can been reestablished.
SM
30km
LMC3045C
LMC3048C

Application Examples:

SM
60km
LMC3046C
LMC3049C
Connector
Distances
RJ-45
Type
UTP
100m
LMC3043C
CUSTOMER
Order toll-free in the U.S.: Call 877-877-BBOX
(outside U.S. call 724-746-5500)
SUPPORT
Fig 1: Redundant Switch Example
FREE technical support 24 hours a day, 7 days
INFORMATION
a week; Call 724-746-5500 or fax 724-746-0746
In this example, redundant Switches 1 and 2 are
Mailing address: Black Box Corporation,
connected to Switch 3 via a 100Tx-2Fx converter. If
1000 Park Drive, Lawrence, PA 15055-1018
power fails in Switch 1, or if there is a loss of link in the
Web site: www.blackbox.com
fiber cable, the 100Tx-2Fx converter switches to
E-mail: info@blackbox.com
transmitting on port B and routes data flow to Switch 2.
Page 1
data transmission to Port A. When the switch is set to “NR”,
Port B will continue to be used for transmitting data even after
LED
link has been reestablished on Port A.
Power:
Port A Link:
Note that modules connected together must be set to
the same mode for correct operation.
Port B Link:
“RJ45 Cross-Over” Switch (not shown):
When connecting the UTP to a hub or switch, set switch to
Port C Link:
“Straight-Through” (factory setting). When connecting to a
Port A Select: Green
workstation, set to “Cross-Over.”
Port B Select: Green
DFCS
modules are hot-swappable and can be installed
UTP Auto:
into any chassis in the
DFCS
family.
UTP FDx:
1. Carefully slide the
DFCS
module into the installation
slot, aligning the module with the installation guides.
NOTE: Ensure that module is firmly seated against
the backplane.
2. Secure the module by securing the panel fastener
screw (attached to module) to chassis front.
3. Attach the UTP port of Port C via a category 5 cable
to a 100Base-Tx Ethernet device.
4.
DFCS
Redundant Fast Ethernet Modules should be
deployed in pairs with Port A linked to Port A and Port
B linked to Port B between the two modules. If using
DFCS
Redundant Fast Ethernet Modules with redundant
Fx or Fx SF ports, attach Port A fiber ports and Port
B fiber ports of the two modules via an appropriate
multimode or single-mode fiber cable. The
DFCS
transmit (Tx) must attach to the receive side on
other device; the receive (Rx) must attach to the
DFCS
transmit. If using
Redundant Fast Ethernet
Modules with redundant Tx ports, attach the UTP
ports of the two modules’ Port A via a category 5
cable and UTP ports of the two modules’ Port B via
a category 5 cable.
Page 7
Redundant Fast Ethernet manageable media
DFCS
product
Redundant Fast Ethernet modules are intended
Fig 2: Redundant Fiber to Customer
In this example, data flow from a core switch at the
Central Office is converted from UTP to redundant
fiber, and converted back to UTP, where it is connected
to an edge switch at the Customer Premises. If there is
a loss of link in fiber Port A, the 100Tx-2Fx converter
switches to transmitting on fiber Port B, without a service
disruption to the mission-critical customer.
Page 2
Color
Description
Model
Yellow
On--Power
Green
On--Link / Blink--activity
Protocols
Steady Blink--Standby mode
Green
On--Link / Blink--activity
Copper Connectors
Steady Blink--Standby mode
Fiber Connectors
Green
On--Link / Blink--activity
On--Active port / Blink--remote
UTP X-over, LS/LP,
side broken
Controls
On--Active port / Blink--remote
side broken
Green
On--Auto-Negotiation enabled
LED Displays
UTP link, SEL, Auto,
Green
On--Full-Duplex detected
Dimensions
Weight
Compliance
Temperature
-Operating
-Storage
Altitude
MTBF (hrs)
Page 8

Link Modes:

In order to accommodate different user needs, the
Redundant DFCSs support four different linking modes.
It is recommended keeping the Redundant
the factory default Link Segment (LS) setting.
Fig 3: Link Segment Mode
In “Link Segment” (LS), sometimes referred to as the
“Normal” mode, a port transmits a “Link” signal
independently of any received “Link” at any other port.
For example, the UTP transmits a “Link” regardless of
the fiber receiving a “Link” [Fig 2(a) & (b)]. Figure 2(a)
shows the state when all links are functioning correctly.
Port A LEDs indicate link and activity, while the Port B
LEDs blink at one Hertz to indicate they are not active,
but are in “Standby”. Figure 2(b) shows that when the
fiber link to Port A is broken, Port B becomes active.
Page 3
Page 4
All applied-for and registered trademarks are the property
100Tx-2Fx
100Tx-2Tx
of their respective owners.
100Base-Fx,
FEDERAL COMMUNICATIONS COMMISSION AND
100Base-Tx
100Base-Tx
CANADIAN DEPARTMENT OF COMMUNICATIONS
RADIO FREQUENCY INTERFERENCE STATEMENTS
RJ-45
RJ-45
This equipment generates, uses, and can radiate radio
SC, ST
-
frequency energy and if not installed and used properly,
that is, in strict accordance with the manufacturer’s
UTP X-over, LS/LP,
instructions, may cause interference to radio
RFD, SFD, UTP
RFD, SFD, UTP
communication. It has been tested and found to comply
Auto/Man, FD/HD
Auto/Man, FD/HD
with the limits for a Class A computing device in accordance
with the specifications in subpart B of Part 15 of FCC
Pwr, FO link,
Pwr, UTP link,
SEL, Auto,
rules, which are designed to provide reasonable protection
FD/HD, RTA
FD/HD, RTA
against such interference when the equipment is op-
erated in a commercial environment. Operation of this
W:0.85" x D:4.5" x
W:0.85" x D:4.5" x
equipment in a residential area is likely to be cause inter-
H:2.8"
H:2.8"
ference, in which case the user at his own expense will be
8 oz.
8 oz.
required to take whatever measures may be necessary to
correct the interference.
UL, CE, FCC
UL, CE, FCC
Class A
Class A
Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
0 to 50 C
0 to 50 C
-40 to 80 C
-40 to 80 C
This digital apparatus does not exceed the Class A limits
0-10,000 ft
0-10,000 ft
for radio noise emission from digital apparatus set out in the
Radio Interference Regulation of the Canadian
1,175,000
1,235,000
Department of Communications.
Le présent appareil numérique n’émet pas de bruits
radioélectriques dépassant les limites applicables aux
appareils numéirques de las classe A prescrites dans le
Règlement sur le brouillage radioélectrique publié par le
ministère des Communications du Canada.
Page 9
Page 10
In “Link Propagate” (LP), sometimes referred to as “Link
Loss Carry Forward”, a port transmits a “Link” signal
only when receiving a “Link” at its other port. For
example, the UTP transmits a “Link” only when receiving
DFCSs
in
a “Link” at the fiber port (Not Shown).
In “Remote Fault Detection” (RFD), the UTP port
transmits a “Link” signal only when receiving a “Link” at
the fiber port. The fiber port transmits a “Link” only
when receiving “Link” signals both at the fiber port and
the UTP port. As a result, fiber faults (no “Link” received
at the fiber) are looped-back and can be reported to the
network’s core (Not Shown).
In “Symmetrical Fault Detection” (SFD), the UTP port
transmits a “Link” signal only when receiving a “Link” at
the fiber port. The fiber port transmits a “Link” only when
receiving “Link” signal both at the fiber port and the UTP
port. As a result, fiber faults (no “Link” received at the fiber)
are looped back and can be reported to the network core. In
addition, connecting two back-to-back converters which are
both set to SFD facilitates dual-loop-back where fiber faults
are reported to both ends of the network (Not Shown).

Board Mounted Dip-Switch Settings:

Fig 4: Board Mounted Dip-Switches
“LS/LP” Link Segment/Propagate Dip-Switch:
This dip-switch controls Link Propagation (LP, sometimes
referred to as LLC--Link Loss Carry Forward) or Link Segment
(LS). In the “ON” position, LP mode is enabled. When in the
“OFF” position (factory default), LS mode is enabled.
Page 5
1. Todas las instrucciones de seguridad y operación deberán ser leídas
antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas
para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones
de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por
ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de
una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o
pedelstales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo
como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico
más allá a lo descrito en las instrucciones de operación. Todo otro servicio
deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición
no interfiera su uso. La colocación del aparato eléctrico sobre una
cama, sofá, alfombra or superficie similar puede bloquea la
ventilación, no se debe colocar en libreros o gabinetes que impidan
el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de
calor como radiadores, registros de calor, estufas u ostros aparatos
(incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo
del tipo descrito en el instructivo de operación, o como se indique en el
aparato.
12. Precación debe ser tomada de tal manera que la tierra fisica y la
polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que
no sean pisados ni pellizcados por objetos colocados sobre o contra
ellos, poniendo particular atención a los contactos y receptáculos
donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las
recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de
las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo
no sea usado por un largo periodo de tiempo.
Page 11
Note that for “LS” mode, “LP”, “RFD” and “SFD”,
dip-switches must be in the Left position (factory
setting).
Note that setting more than one of the mode switches
(“LP”, “RFD” or “SFD”) to the Right position on the
same module is an illegal mode that will result in
unpredictable behavior.
“RFD” Remote Fault Detection:
When in the “RFD” position, the Remote Fault Detection
(RFD) mode is enabled.
Connecting two converters with both set to RFD
mode is illegal and will cause a “deadly embrace”
lockup.
“SFD” Symmetrical Fault Detection:
When in the “SFD” position, the Symmetrical Fault
Detection (SFD) mode is enabled. Note that for the
DFCS
Redundant Fast Ethernet modules when loss of “Link”
occurs between two modules, both redundant connections
must have a loss of incoming “Link” signal in order for this
to occur.
“AN/MAN” UTP Auto/Manual Switch:
Setting this dip-switch to “Auto” (factory setting) enables the
UTP Port C to determine the mode automatically. This feature
allows connections with devices that do not auto-negotiate
properly.
“FD/HD” UTP Full/Half Duplex Switch:
When the “Auto/Manual” dip-switch is in “Manual” position,
the “UTP Full/Half Duplex” dip-switch determines the duplex
operation mode for the UTP port. When set to “Full
Duplex” (factory setting), the UTP port will operate in full
duplex. When set to “Half Duplex” the UTP port will operate
in half duplex. Adjust the half/full-duplex switch to match
the connecting device and check for link status.
“RTA/NR” Return to Port A Switch:
When the “Return to Port A” switch is in “RTA” position (factory
default), link reestablishment on Port A will immediately return
Page 6
17. Cuidado debe ser tomado de tal manera que objectos liquidos no
sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato;
o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio
en su desempeño; o
E: El aparto ha sido tirado o su cubierta ha sido dañada.
©Copyright 2003. Black Box Corporation. All rights reserved.
1000 Park Drive
Lawrence, PA 15055-1018
·
724-746-5500
Fax 724-746-0746
·
040-L3043-001A 12/03
Page 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DFCS 100Tx-2Fx and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Black Box DFCS 100Tx-2Fx

  • Page 1 Port A via a category 5 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las cable and UTP ports of the two modules’ Port B via ©Copyright 2003. Black Box Corporation. All rights reserved. recomendaciones del fabricante. a category 5 cable.
  • Page 2 Port A via a category 5 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las cable and UTP ports of the two modules’ Port B via ©Copyright 2003. Black Box Corporation. All rights reserved. recomendaciones del fabricante. a category 5 cable.

This manual is also suitable for:

Dfcs 100tx-2tx

Table of Contents