50.0 to 57.0 VDC Voltage range at PD 37.0 to 57.0 VDC 42.5 to 57.0 VDC 42.5 to 57.0 VDC 1.2 LGC5600A MEDIA CONVERTER LGC5600A Description Gigabit Media Converter with 802.3bt 60W, AC power, Commercial temperature range IEEE 802.3, Standard Compliances IEEE 802.3af (15.40 watts max), IEEE 802.3at (30 watts max),...
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 1: SPECIFICATIONS TECHNICAL SUPPORT 1.877.877.2269 1.3 LGC5700A INDUSTRIAL MEDIA CONVERTER LGC5700A Description Gigabit Media Converter with 802.3bt 60W, DC power, Industrial temperature range IEEE 802.3, Standard Compliances IEEE 802.3af (15.40 watts max), IEEE 802.3at (30 watts max), IEEE 802.3bt (60 watts max) PoE++ Supported Modes IEEE Alternate A (Alt A) and 4 Pair...
Equipment that provides DC power over twisted-pair cable is called Power Sourcing Equipment (PSE). Equipment that is powered over twisted-pair cable is called a Powered Device (PD). The LGC5600A and LGC5700A are PSE equipment supporting IEEE 802.3af PoE, IEEE 802.3at PoE+, and IEEE 802.3bt PoE++ 60 W on the RJ-45 port.
SFP, 1.25-Gbps, 1310nm Singlemode Fiber, 20 km, LC 20 km NOTES: 1. All Black Box SFPs feature Extended Diagnostics (excluding LFP441 and LFP442). 2. Black Box Media Converters also support generic SFPs. 2.2 INSTALLATION PROCEDURE OVERVIEW 1. Configure DIP switches 2.
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 3: INSTALLATION TECHNICAL SUPPORT 1.877.877.2269 3. INSTALLATION STEP 1: CONFIGURE DIP SWITCHES DIP switches are located on the side of the module. The DIP switches are used to configure ports, link modes, and PoE++/PSE options. DIP SWITCH BANK LOCATIONS The table below provides a description of each DIP switch position and function.
Page 8
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 3: INSTALLATION TECHNICAL SUPPORT 1.877.877.2269 SW1 - Fiber Speed: Auto/100 This DIP switch configures the speed of the transceiver installed in the SFP receptacle. If this DIP switch is in the DOWN “Auto” (default) position, the port will automatically detect the data rate of the transceiver installed and operate at 100 Mbps or 1000 Mbps accordingly.
Page 9
These DIP switches must be left in the DOWN (default) position. SW12 and SW13 - Link Modes The LGC5600A and LGC5700A feature Link Segment and Asymmetrical Link Propagate fault detection modes. Link Segment In Link Segment mode, all ports operate independently. A loss of a receive link signal will only affect the port detecting the loss of signal.
Installation of the equipment should be such that the air flow in the front, back, side and top vents of the chassis are not compromised or restricted. Secure the grounding wire to the ground screw. See the figure below for the location of the grounding screw. REAR VIEW OF THE LGC5600A WITH AC POWER CONNECTOR WARNING!!! NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE POWER SUPPLY.
Page 11
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 3: INSTALLATION TECHNICAL SUPPORT 1.877.877.2269 WARNING REGARDING EARTHING GROUND: This equipment shall be connected to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode is connected.
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 TECHNICAL CHAPTER 3: INSTALLATION SUPPORT 1.877.877.2269 STEP 3: CONNECT CABLES Insert the SFP transceiver into the SFP receptacle on the front of the module. NOTE: The release latch of the SFP Fiber transceiver must be in the closed (up) position before insertion. b.
Page 13
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 CHAPTER 3: INSTALLATION TECHNICAL SUPPORT 1.877.877.2269 FIBER PORT LED INDICATORS Legend Indicator Description No link Green - ON Port linked at 100 Mbps Green - Blinking at 10 Hz Port data activity at 100 Mbps Green - Blinking at 1 Hz Port linked at 100 Mbps and in redundant standby mode Amber - Blinking at 1 Hz...
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 APPENDIX A: REGULATORY INFORMATION TECHNICAL SUPPORT 1.877.877.2269 A.1 FCC STATEMENT This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment.
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 APPENDIX A: REGULATORY INFORMATION TECHNICAL SUPPORT 1.877.877.2269 A.2 NOM STATEMENT 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3.
B.1 DISCLAIMER Black Box Corporation shall not be liable for damages of any kind, including, but not limited to, punitive, consequential or cost of cover damages, resulting from any errors in the product information or specifications set forth in this document and Black Box Corporation may revise this document at any time without notice.
Page 17
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 NOTES TECHNICAL SUPPORT 1.877.877.2269 1.877.877.2269 BLACKBOX.COM...
Page 18
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 NOTES TECHNICAL SUPPORT 1.877.877.2269 1.877.877.2269 BLACKBOX.COM...
Page 19
NEED HELP? LEAVE THE TECH TO US LIVE 24/7 NOTES TECHNICAL SUPPORT 1.877.877.2269 1.877.877.2269 BLACKBOX.COM...
Need help?