Configuring E1 Module
Before configuring E1 module, the system carrier type must be changed to E1
by using 'system carrier-type' command in the configuration terminal mode.
After setting the system carrier type, the system must be reboot to take effect.
The following steps sets a few communication modes and port information for
a E1 interface.
Configuring Step
Step
1
2
3
4
5
6
7
8
9
10
© SAMSUNG Electronics Co., Ltd.
Command
Router# configure terminal
Router/configure# module e1
[slot/subslot/port]
Router/configure/module/e1(slot/su
bslot/port])# circuitId [circuit ID]
Router/configure/module/e1(slot/su
bslot/port])# contactInfo [Contcat
Information]
Router/configure/module/e1(slot/su
bslot/port])# description
[Description]
Router/configure/module/e1(slot/su
bslot/port])# framing
{crc|noncrc|disable}
Router/configure/module/e1(slot/su
bslot/port])# linecode {hdb3 | ami}
Router/configure/module/e1(slot/su
bslot/port])# clock_source {line |
internal}
Router/configure/module/e1(slot/su
bslot/port))# end
Router# show module configuration
e1 [slot/subslot/port]
Ubigate iBG2016 Configuration Guide/Ed.00
Purpose
Enters the terminal configuration
mode.
Selects a E1 module port.
Sets a circuit ID.
Sets contact information such as
manager's name or number.
Sets an interface description.
Selects a framing mode
Selects a linecode mode
Selects a clock source.
Goes back to the 'Router#'
prompt.
Shows E1 module information.