CHAPTER 6. Digital Voice Port
Wink-Start signaling
Immediate-Start signaling
540
Originating
M-wire
E-wire
1111
seizure
1111
0000
digits
digits
1111
Figure 6.10 Wink-start method signaling sequence
Originating
M-wire
E-wire
1111
seizure
digits
digits
1111
Figure 6.11 Immediate-start method signaling sequence
Destination
M-wire
E-wire
Start dial
answer
Destination
M-wire
E-wire
answer
Min 120 msec
Max 6 sec
Duration 200 msec
Min 70 msec
Max 10 sec
Min 200 msec
Min 120 msec
Max 10 sec
Min 200 msec
© SAMSUNG Electronics Co., Ltd.