Secm Field Update With Service Tool - Doosan G424FE Service Manual

Lp and lp/dual fuel engines
Table of Contents

Advertisement

SECM field update with Service Tool

SECM controllers can be upgraded in the field using
MotoUpdate software. Typically, MotoUpdate and
MotoViewer applications are packaged together in
the MotoService software application.
upgrade files may be released to the field to
enhance performance, provide additional features,
and/or correct software problems.
This document provides step-by-step instructions for
upgrading a SECM using MotoUpdate software. In
order to illustrate the process, the following example
upgrade is used throughout this document.
Current SECM software version:
VARSPEDDRAAF-01-2-5-D-000-000.siz (calibration ID)
Upgrade to software version:
VARSPEDDRAAG-01-2-5-D-000-000.siz (calibration ID)
Using field update file:
VARSPEDDRAAG -01-1-5-D-000.mfu
NEW Corresponding DLL file:
VARSPEDDRAAG.dll
STEP1 - LOAD UPDATE FILES INTO THE
APPROPRIATE DIRECTORY
Software upgrade packages include an upgrade file
(.mfu) and translation file (.dll). The (.mfu) file is
required to upgrade the module, and the (.dll) is
required by MotoViewer software to communicate
with the module after the upgrade. Therefore, both
files are provided together. Copy the field update
file (.mfu) to the C:/ECUF Files/Updates directory,
and
the
corresponding
Files/TDBDLL.
G424F(FE) Service Manual
Software
(.dll)
file
to
C:/ECU
Copy the .dll file to the
TDDBLL directory
Copy the .mfu update file to
the Updates directory
293