travel limit mechanical stops.
Make sure that at the end of both the opening and closing manoeu-
vre, the relevant travel-limit LED stays active (LED OFF).
 Make the appropriate modifications to the positions of the travel-limit
magnets.
7. AUTOMATED SYSTEM TEST
After installing the operator, carefully check operating efficiency of all
accessories and safety devices connected to it.
Return the board support to its original position. Fit the cover, Fig. 20, and
tighten the two side screws provided, Fig. 20 ref .
Apply the danger sticker on the top of the cover (Fig. 21).
Hand the "User's Guide" to the Customer and explain correct operation
and use of the gearmotor, indicating the potentially dangerous areas of
the automated system.
Fig. 20

8. MANUAL OPERATION

The manual release is a device that makes it possible to disconnect
the operator from the gate, thus enabling manual movement.
Before using the release device, cut power to the system, with the
differential switch upstream of the gearmotor.
THE RELEASE DEVICE MUST NOT BE CONSIDERED AN EMERGENCY STOP
If the gate has to be moved manually due to a power cut or fault of the
automated system, use the release device as follows:
1. Fit the supplied key in the lock, Fig. 22 Ref. , and turn it clockwise as
shown in Fig. 22 Ref. .
2. Turn the release system clockwise by about 180°, as shown in Fig. 22 Ref. .
3. Open and close the gate manually.

9. RESTORING NORMAL OPERATION MODE

To prevent an involuntary pulse from activating the gate during the
manoeuvre, cut power to the system before re-locking the opera-
tor.
1. Turn the release system anti-clockwise by about 180°, as shown in Fig.
23 ref. .
2. Turn the key anti-clockwise, Fig. 23 ref. , and remove it from the lock, as
shown in Fig. 23 ref. .
3. Move the gate until it meshes to release.
Before powering up the system again, make sure that the gate cannot
be moved manually.

10. SPECIAL APPLICATIONS

There are no special applications.
Anything not expressly specified in these instructions is expressly
prohibited
To ensure correct long-term operation and a constant level of safety, we
advise you to generally control the system every 6 months. In the "Use Instruc-
tions" booklet, there is a form for recording maintenance jobs.
The enclosed maintenance form is purely a guideline; it cannot be ruled
out that to guarantee a correctly operating automated system and
a constant level of safety, maintenance operations not described
in this form may be necessary.
The User must not in any way attempt to repair or to take direct action and
must solely contact qualified GENIUS personnel or GENIUS service centres.
For accessories, see the GENIUS catalogue.
Fig. 21
Fig. 22
Fig. 23
10

11. MAINTENANCE