Battery Storage - PSC Power Star Operation Manual

Power distribution platform
Table of Contents

Advertisement

Pelican case batteries that are equipped with Neutrik Speakon connectors rather
than 4 pin XLR connectors. Standard 4 pin XLR connectors are only rated for
use at up to 9 amps of current. As the Power Star can charge at up to 15 amps
per battery connection, the use of Speakon connectors is highly recommended.

BATTERY STORAGE:

Always make sure to charge your batteries before putting them into storage.
Your batteries should not be allowed to go below 10.6Vdc for any extended
period of time.
Doing so will permanently damage them.
Because all
rechargeable batteries slowly self discharge while in storage, it is recommended
that you charge them every two to three months when you are not using them for
extended periods of time. This will ensure that the batteries never self discharge
to a damaging level.
POWER STAR USE:
The PSC Power Star is designed for use in powering your entire digital audio
recording package.
The Power Star's ten (10), 4-pin female XLR output
connectors provide output voltage at all times when the Power Star is switched
on. All power cables wired for use between the Power Star and your equipment
must be wired correctly and professionally.
Anytime the Power Star is plugged in, its battery charger is operational. Your
battery may be charged without the Power Star's front panel electronics being
turned on. By switching "ON" the power switch on the small remote control box,
the Power Star will turn on and begin to supply power to your equipment. If the
Power Star is connected to a battery, but not plugged into AC, all of the power
will come from the battery. If the battery is discharged below a safe point, the
Power Star will not turn on when the power switch is set to "ON". If the battery
level is good, the Power Star will operate normally. When the batteries are
discharged to the point where they are in danger of being damaged due to over
discharge, the Power Star will automatically shut itself off and disconnect the
load. This low battery shut off occurs at approximately 10.8 Volts as read
on the meter. You can also shut off the Power Star at any time by simply turning
the main power switch to "OFF". The power switch is centered between the
Voltage and Current meters on the small remote control box. The box has built
in overhangs to prevent accidental switching of the main power switch. You can
also operate the Power Star without a battery connected by simply plugging the
Power Star into AC and switching "ON" the main powers switch. The Power Star
will power your equipment at up to 15 amps current consumption (approximately
225 watts of total output power) when connected to AC only.