battery is being used. Typical readings are 14.4 volts DC when the battery is
fully charged, ranging down to 10.8 volts DC when the PSC Power Star is ready
to shut down due to low battery charge.
When connected to AC, the readings
will typically be 13.6 to 14.4 volts DC.
The DC Current Meter reads total
equipment current consumption in DC Amps.
For example if your entire
connected equipment package consumes 8 Amps, this meter will reflect that
amount.

RACK MOUNTING:

The PSC Power Star is designed to be rack mounted. The rack mount brackets
are removable for use when the unit is not rack mounted. The rack mount
brackets are designed for two position mounting.
Allowing the unit to be
mounted flush to the front of the rack or mounted so that the output connectors
are recessed within the rack. Simply remove the 4 rack mount bracket screws
and re-position the brackets to suit your needs.
Rack Mount Brackets Shown in Standard and Recessed Positions:
CHARGING:
The PSC Power Star contains a built in charger designed to charge external
Sealed Lead Acid (SLA) batteries. These external batteries can be the industry
standard 12V, 33AH Pelican battery boxes or large Deep Cycle batteries such as
Optima Yellow Top batteries. The PSC Power Star will operate from a wide