Carrier CAPRI-280 Operation And Service Manual page 36

Bus air conditioning equipment
Table of Contents

Advertisement

Configuration
A.
High Reheat --- When this configuration is removed the unit will default
to high speed in reheat mode and in the low speed cool band. If not
removed heat reheat will default to low speed.
B.
High Vent --- When this configuration is removed the unit will default to
high speed in vent mode. If not removed vent mode will default to
low speed.
C.
NA
D.
Reheat/Cycle --- When the reheat cycle configuration is removed the
unit is in reheat mode. The default configuration is cycle clutch
mode.
E.
Transducers --- When the transducer configuration is removed trans-
ducers will assumed to be present.
F.
NA
G.
Unit Type --- SEPTA unit enabled with G in and H removed
H.
Unit Type --- SEPTA unit enabled with G in and H removed
I.
NA
J.
NA
K.
Voltage --- When this configuration is removed the voltage selection
will be changed from 12 to 24V DC.
L.
NA
M.
NA
N.
C/F --- When this configuration is removed the display will show
temperatures in F. When not removed the display will show tempera-
ture in C.
O.
NA
P .
NA
T-283
Table 4-3. Controller Configuration
Description
4-10
Jumper
REMOVED
REMOVED
IN
REMOVED
REMOVED
IN
IN
REMOVED
NA
IN
REMOVED
REMOVED
IN
REMOVED
IN
IN

Hide quick links: