ALARM
TITLE
NO
25
Motor Failure
26
Not used
31
Maintenance Alarm 1
32
Maintenance Alarm 2
99
Alarm Queue Full
T-283
Table 3-2. Alarm Codes (Continued)
CAUSE
A motor has not reached
full operating speed or
the condenser motors
have shut down due to a
pressure alarm or the
motor fuse has blown.
The compressor hour
meter is greater than the
value in Maintenance
Hour Meter 1.
The evaporator hour
meter is greater than the
value in Maintenance
Hour Meter 2.
All locations of the alarm
queue are currently full
and no more alarms can
be saved.
3-3
REMEDY
Replace motor, or cor-
Alarm displayed and the
rect pressure shutdown.
motor fail output is ener-
gized.
Reset the maintenance
Alarm will be generated.
hour meter.
Reset the maintenance
Alarm will be generated.
hour meter.
Record and clear alarm
Alarm will be generated.
queue.
CONTROLLER
RESPONSE