Worcester GREENSTAR CAMRAY EXTERNAL 12/18 Instruction Manual page 39

Floor standing external oil fired condensing boiler using balanced flue system installation commissioning & servicing
Hide thumbs Also See for GREENSTAR CAMRAY EXTERNAL 12/18:
Table of Contents

Advertisement

B
C
5mm
5mm
B
E
RIELLO
RDB OIL PUMP
G
Brass air deflection washer
H
G - Retaining screws - cover
H - Cover - oil pump
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR CAMRAY EXTERNAL 12/18-18/25-25/32
8 716 112 700a (02.07)
A
D (on 12/18 and 18/25 models only)
F
E
C
(D on 25/32 model only)
Electrode gap
3.5 - 4.0mm
E
C
2.0 - 2.5mm
(on 12/18 model only)
Locating circlip
INSPECTION AND SERVICE
1 Clean the Burner:
Remove the air intake cover (A) and clear
any debris from the air intake and air damper.
Disassemble the burner to allow access to
the fan impeller.
Check the condition of the gaskets between
these parts and replace if necessary.
Note the position of the air damper
adjustment and check the air damper moves
freely.
Clean both sides of the fan impeller and
remove any debris from the burner housing.
Check that the impeller rotates freely.
Reassemble the components.
Remove the combustion head (B) and
thoroughly clean any deposits.
IMPORTANT: Before removing or fitting a
nozzle (C), loosen screw (D) and move
the electrodes (E) forward.
After refitting check that the electrode
gaps are correct, as shown opposite.
Remove the nozzle (C).
Check the nozzle holder is clear of any debris
and clean if neccessary.
Fit a new oil atomising nozzle (C).
DO NOT dismantle the nozzle and DO NOT
clean the nozzle tip.
Check the electrodes (E) and reset if
necessary as shown opposite.
NOTE: The 12/18 model has a brass air
deflection washer and locating circlip behind
the nozzle. These must be in place for the
correct operation of the burner.
Refit the combustion head (B). Check that
the nozzle (C) lies central to the combustion
head (B) and the head settings are as
shown. Ensure that the photocell is lined up
with the sight hole.
Withdraw the photocell (F) from its housing
and wipe clean.
Remove the oil pump internal filter, clean in
kerosene and reassemble.
The internal filter is accessed by removing
screws (G) and the oil pump cover (H).
Replace the standard flexible oil line/s at
E
every annual service to prevent the possibility
of leakage due to ageing.
C
Reassemble the burner components.
Check the O-ring seal located around the
combustion head and replace if necessary.
This seal must be in good condition, seal
failure will cause flue gases to escape into
the cabinet.
INSPECTION AND SERVICE
38

Advertisement

Table of Contents
loading

Table of Contents