Nip Band Width Measurement (Sp) - Ricoh B205 Service Manual

Hide thumbs Also See for B205:
Table of Contents

Advertisement

SERVICE PROGRAM MODE
5.1.11 NIP BAND WIDTH MEASUREMENT (SP1109)
When paper wrinkling or image off-set occurs, the pressure from the pressure roller
can be adjusted by changing the position of the pressure springs. At this time, the
nip band width can also be checked with SP1109, as follows.
1. Do a free run (SP5802) for about 50 sheets.
2. Access SP1109 and press the "1" key.
3. Press Copy Window to return to the copy window.
4. Place an OHP sheet (A4/8.5"x11" sideways) on the by-pass tray or in the 2nd
paper tray.
5. Press the "Start" key.
The OHP sheet is stopped in the fusing unit for about 20 seconds, then it will be
fed automatically.
6. Check the nip band width [A]. The relationship between the position of the
pressure spring and the band width is as follows.
NOTE: Check the nip band width around the center of the OHP.
1. Pressure spring position
Upper (default position)
Lower
2. Envelope feed mode (green lever down) at the
default pressure spring position
If the width is out of the above specification, the pressure spring should be
replaced.
B205/B209/D007/D008
OHP
5-128
Nip band width
5.2 ± 0.5 mm
5.3 ± 0.5 mm
4.7 ± 0.5 mm
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B209D007D008

Table of Contents