3-6. The adjustment item which in necessary in part exchange
Lens
Adjustment
COMPL PWB CP-1
COMPL PWB ST-1
COMPL PWB VF-1
COMPL PWB TB-1
ASSY FLEXIBLE
PWB CA1
LENS ASSY
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
3-7. Adjust Specifications
1. Lens Adjustment
Camera
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set the camera 0 cm from the collimator. (Do not enter any
light.)
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Click the Focus, and click the Yes.
5. Lens adjustment value will appear on the screen.
6. Click the OK.
CCD White Point
AWB
Defect Detect
Adjustment
Adjustment
Collimator
CCD Black Point
And White Point
Factory
Defect Detect
Cord
Adjustment In
Setting
Lighted
DscCalDi
!
Adjustment value determination is effectuated using the "STD
AFPOS", "FOCUS" and "LENS_ERR" values.
If FOCUS=focus1, focus2, focus3, focus4 and the adjustment
values fulfill the conditions below, they are determined as within
specifications.
Adjustment value determination
1800<=STD_AFPOS<2000
-40<=focus1<=+40, -50<focus2<+50,
-60<=focus3<=+60, -200<=focus4<=+200
lens_error=0
– 18 –
USB storage
Language
information
Setting
registration
x
Focus Result
STD_AFPOS=1905
FOCUS=-4,-6,-17,-77
ADJ_PZPOS=-11
LENS_ERR=0
OK
Reset