Check method
Error type
The main heat
exchanger is
clogged.
Thudding
noise caused
by circulation
error
Defective
overheat
Defective
safety device
The temperature
Defective
fuse is discon-
safety device
©Navien America Inc. 2010
Cause
Separate inlet/outlet pipe of the main heat exchanger, and blow air
with mouth to check if the pipe is clogged.
<Check if the main heat exchanger is clogged.>
Check if the contact point of the overheat PCB is defective.
Use a tester to see if the resistance is normal (0 Ω) or abnormal (∞).
PCB
<Overheat controller>
Check, with a tester, if the temperature fuse is disconnected.
If the fuse is disconnected, replace the part and check the
nected.
cause of overheating.
NR/NP series service Manual
Check method
<Check if the overheat controller wire is disconnected.>
93
Version 2.0