Thermal Fuse - Navien NP-180 Service Manual

Nr/np series tankless gas water heater
Table of Contents

Advertisement

4.6.2. Thermal Fuse

Navien Part No.
Function
Failure Event
Effects
Error Code
Diagnostic
Color /
Number of wires
©Navien America Inc. 2010
BH1419012A
BH1419013A
1. It protects over limited high temperature in burner due to abnormal operations.
2. The thermal fuse contains solder with a melting point of 383
3. Detects excessive temperature within the unit, especially around the
heat exchanger and combustion chamber. Upon detection, communication
between the PCB and gas valves will sever, shutting down the unit instantly.
1. Unable to detect the excessively high temperature within the unit
1. Flames from burner may penetrate a ruptured/damaged heat exchanger.
2. The water heater is not operating.
N/A
1. Visual inspection: Connection and/or breakage of wires.
2. Voltage check: Check range of voltage shown below.
Black - Black
44
NR/NP series service Manual
Check Point
(195 ).
N/A
Version 2.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents