Navien NP-180 Service Manual page 37

Nr/np series tankless gas water heater
Table of Contents

Advertisement

#2 Dip Switches
No
Function
Ready-Link
1
Multi-System Selection
2
Location select
3
X
4
Pump &
Recirculation Selection
5
6
Model Select
7
Temperature Select
8
Pump and Recirculation Modes Selection
With Pump
(NR-180A, NR-210A, NR-240A,
NP-180A, NP-210A, NP-240A)
(NR-180, NR -210, NR -240,
NP-180, NP -210, NP -240)
Temperature Selection
With Pump
(NR-180A, NR-210A, NR-240A,
NP-180A, NP-210A, NP-240A)
˚F (˚C)
110 (43)
120 (49)
130 (54)
140 (60)
©Navien America Inc. 2010
Description
ON
Ready-Link
Multi-System Master
Korea
See " Pump and Recirculation Modes Selection "
Description
No Recirculation
External Recirculation
Internal Recirculation
Without Pump
Temperatures
Premium
Models
(NP,NP-A Series)
˚F (˚C)
120 (49)
140 (60)
160 (71)
185 (85)
35
NR/NP series service Manual
Single Unit Operation or
Multi-System Slave
North America
X
Factory setting
See " Temperature Selection "
DIP Switch #
4
OFF
OFF
ON
ON
DIP Switch #
7
OFF
OFF
ON
ON
OFF
X
5
OFF
ON
OFF
ON
8
OFF
ON
OFF
ON
Version 2.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents