Operation
1. Water Flow Begins
•
Water Flow Sensor sends pulses to the PCB.
•
PCB senses flow greater than 0.5 GPM (0 GPM for "A" Model) (approximate).
•
Firing Sequence begins.
2. Firing Sequence
•
PCB monitors Inlet / Outlet water temperature, temperature set point,
and water flow rate.
•
Fan Motor energized. Purges combustion chamber.
•
Spark igniter begins sparking
•
Main Gas control valve opens to minimum fire rate.
•
Flame rod proves ignition.
•
Spark igniter stops sparking.
3. Normal Operation
•
PCB monitors flame rod, fan motor frequency, outlet water temperature,
PCB temperature set point and water flow rate.
•
Main Gas control valve modulates gas input to required firing rate.
•
Combustion fan speed is adjusted for the required firing rate.
•
Water adjustment valve is adjusted as needed.
4. Shut-down Sequence
•
PCB senses flow rate less than 0.5 GPM (0 GPM for "A" Model) (approximate).
•
Main Gas Control valve closes.
•
Water adjustment valve resets to standby position.
•
Combustion fan runs for a short period of time at low speed.
5. Standby Mode
•
PCB monitors water temperature and remote controls.
•
Freeze protection is activated as needed.