Miscellaneous Selections One; Miscellaneous Selections Two - Texecom Veritas 8 Installation Manual

Security control panels
Hide thumbs Also See for Veritas 8:
Table of Contents

Advertisement

Programming the Control Panel

Miscellaneous Selections One

From the Programming Menu, enter
show the options currently selected.
Zon es
1 2 3 4 5 6 7 8
Press the appropriate numbered button to select or de-
select the corresponding option as shown on the display.
Press
. The system will chime to confirm that the
,
new options have been accepted. The system will then
automatically revert to the Programming Menu.
Option
Miscellaneous Selections One
1
Internals Only on Unset Tamper Alarm
2
Internals Only on Part Set Zone Alarm
3
Internals Only on Part Set Tamper Alarm
4
Silent Part Set (no exit tone on part set)
5
High Level Chime (chime at full volume)
6
Invert Bell Output
7
Final Door Set
8
Unlock Engineer
Option 1 - Internals Only on Unset Tamper Alarm
When 'ON' a tamper alarm when unset will only activate the
internal sounders.
Option 2 - Internals Only on Part Set Zone Alarm
When 'ON' an alarm when part set will only activate the
internal sounders.
Option 3 - Internals Only on Part Set Tamper Alarm
When 'ON' a tamper alarm when part set will only activate
the internal sounders.
Option 4 - Silent Part Set
When 'ON' no exit tones will be heard when the alarm is
being part set.
Option 5 - High Level Chime
When 'ON' chime tones are always full volume.
Option 6 - Invert Bell Output
When 'ON' the bell output will be negative removed instead
of negative applied.
Option 7 - Final Door Set
When 'ON' the alarm will set 3 seconds after the entry/exit
door is closed.
Option 8 - Unlock Engineer Code
When 'ON' Re-loading the Factory Settings WILL restore
the default Engineer code. If Option 8 is de-selected (Zone
8 light is off) then Re-loading the Factory Settings WILL
NOT restore the default Engineer code.
!"
Locked Engineer codes cannot be unlocked without
the correct Boss Engineer code.
Unlocking a locked Engineer code that has been lost
is subject to a minimum charge.
#"
Disclaimer
It is the responsibility of the Installer to guard against
losing locked Engineer codes. Texecom accept no
liability whatsoever for any loss resulting from locked
Engineer codes.
18
!#
. The display will
!#
U n set
T am per
Default
On
On
On
Off
Off
Off
Off
On
Veritas 8, 8C & R8 Installation Manual

Miscellaneous Selections Two

From the Programming Menu, enter
show the options currently selected.
Zon es
1 2 3 4 5 6 7 8
Press the appropriate numbered button to select or de-
select the corresponding option as shown on the display.
Press
. The system will chime to confirm the new
,
options have been accepted. The system will then
automatically revert to the Programming Menu.
Option
Miscellaneous Selections Two
1
Engineer Reset on Any Alarm
2
Engineer Reset on Tamper Alarm
3
Disable User Ability to Omit Tamper
4
Code PIN Tamper
5
Random Number Remote Reset
6
Push To Set
7
Strobe Flash on Full Set
8
Invert Switched Positive Output
Option 1 - Engineer Reset on Any Alarm
When 'ON' the user is prevented from resetting the system
after an alarm activation.
Engineer Reset can be cleared by:
Entering an Engineer code
Entering an RNRR code (if selected - Option 5)
!"
Engineer Reset is not in itself a method of resetting
the system a subsequent User Reset will still be
required as follows:
After an Alarm has been Silenced:
Pressing
(unless EN 50131-1 Requirements is
.
selected - see page 17)
Entering a User code
At other times:
Entering a User code and pressing
!"
When an Engineer Reset is required the user can still
silence the alarm and cancel the strobe but cannot
reset the system.
RNRR and Remote Reset are methods of clearing
Engineer Reset. They will not function unless at least
one Engineer Reset is selected.
Option 2 - Tamper Alarm Engineer Reset
When 'ON' the user is prevented from resetting the system
after a tamper alarm has occurred (for details on Engineer
Reset see Option 1).
Option 3 - Disable User Ability to Omit Tampers
When 'ON' users cannot omit tampers.
Option 4 - Code PIN Tamper
When 'ON' a tamper alarm is generated after 16 invalid key
presses when unset.
!$
!$
. The display will
U n set
T am per
Default
Off
Off
Off
Off
Off
Off
On
Off
.
INS034