5-5. Registering Reference Files
Initializing Only Specified Items Using the Setup Menu (Refer to step 4 of Fig. 5-4.)
References files for specified items can be initialized using the setup menu.
(1) Set the setup menu as follows.
[FILE] → [FILE|CLEAR] → [10|SEC|CLEAR] → [ON]
(2) Move to the page containing the items to be initialized from the reference files in the setup menu.
(3) Adjust "→" to the item to be initialized using the rotary encoder, and keep pressing the rotary
encoder about 10 seconds at "?" state until "REF CLEAR " is displayed. About 3 seconds later,
"DATA CLEAR" will be displayed at the bottom most line. The "REF CLEAR" is displayed about
10 seconds later, and the data will be initialized to 0.
n
The 10 SEC CLEAR function must always be set to OFF when the power is turned ON.
Camera unit
Current paint data
Output to hardware
5-8
Storing in
memory stick
(Step 1)
Storing
(Step 1)
Reference File
Calling
(Step 2)
Fig. 5-4. Operating Procedure for Reference Files
Memory stick
Readng from
memory stick
(Step 3)
Initialization
(Step 4)
Reference File
factory-set value
(Initial value 0)