Tablet and external interface for matrix switch. (20 pages)
Summary of Contents for FSN FS-L190 D
Page 1
MEDICAL LCD MONIT MEDICAL LCD MONIT USER'S GUIDE Before connecting, operating or adjusting this product, please read this instruction booklet carefully and completely. Rev. 4.0, August 20113...
Page 2
MEDICAL LCD MONITOR FS-L190*D (19”) FS-L190*DT(19”) FS-L240*D (24”) FS-L240*DT(24”) FS-L260*D (26”) FS-P260*D (26”) FS-L320*D (32”) FS-L420*D (42”) FS-L550*D (55”) Model definition F S- L X X X * D T 1. FS : Monitor manufacturer. 2. L : Panel manufacturer. 3.
Symbol Definitions The following symbols appear on the product, its labels, or the product package. Each symbol carries a special definition, as defined below. Dangerous : High Voltage. Consult accompanying documents. Direct Current. Power adaptor. lndicates protective earth ground. lndicates equipotential earth ground. DC Power control switch.
Page 5
Humidity limitation. Temperature limitation. Atmospheric pressure limitation. Indicates proof of conformity to applicable European Economic Community Council directives and to harmonized standards published in the official journal of the European Communities. Medical LCD monitor is in accordance with UL 60601-1 and CAN/CSA C22.2 No.601.1 in regards to electric shock, fire hazards, and mechanical hazard.
Safety Instructions On Safety 1. Before connecting the AC power cord to the DC adapter outlet make sure the voltage designation of the DC adapter corresponds to the local electrical supply. 2. Never insert anything metallic into the cabinet openings of the medical LCD monitor.
Page 7
Warning This medical LCD monitor is intended for connection to input/output signals and other connectors that comply with relevant IEC standard (e.g.,IEC60950 for IT equipment and IEC60601 series for medical electrical equipment). In addition, all such combination-system shall comply with the standard IEC 60601-1-1, safety requirements for medical electrical systems.
Page 8
10. Do not use other cable or accessary that are not provided. 11. Do not lay this monitor on the other equipment. Environmental Conditions for operation and Storage - Temperature range within 0°C to 40°C(operation), -20°C to 60°C(storage) - Relative humidity range 10% to 85% Atmospheric pressure range within 500 to 1060hPa.
CAUTION This symbol alerts the user that important literature concerning the operation of this unit has been included. Therefore, it should be read carefully in order to avoid potential problems. This symbol warns user that un-insulated voltage within the unit may have sufficient magnitude to cause electrical shock.
Page 10
EEC Safety Compliance This medical LCD monitor unit meets the requirements of EN-60601-1 so as to conform to the Medical Device Directive 93/42/EEC (general safety information). Use 120V rating 5-15P type plug only in the U.S This medical LCD monitor complies to the above standards only when used with the supplied medical grade power supply.
Page 11
Cleaning Instructions Follow your hospital protocol for the handling of blood and body fluids. Clean the display with a diluted mixture of mild detergent and water. Use a soft towel or swab. Use of certain detergents may cause degradation to the labels and plastic components of the product.
FCC Information This medical LCD monitor unit has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against interference. This monitor can radiate radio frequency energy and, if not installed and used in accordance with the instructions, it may interfere with other radio communications equipment.
Page 13
1. Guidance and manufacturer's declaration - electromagnetic emissions The medical LCD monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the medical LCD monitor should assure that it is used in such an environment. Emission test Electromagnetic environment -guidance Compliance...
Page 14
Surge 1kV differential mode 1kV differential mode Mains power quality should be that of a IEC 61000-4-5 2kV common mode 2kV common mode typical commercial or hospital environment. Portable and mobile RF communications Conducted RF 3 Vrms 3 Vrms equipment should be used no closer to any IEC 61000-4-6 150 kHz to 80MHz 150 kHz to 80MHz...
Page 15
Immunity test Compliance level Electromagnetic environment -guidance IEC 60601 Test level Recommended separation distance 80MHz to 800MHz 80MHz to 2.5GHz Radiated RF 3 V/m 3 V/m IEC 61000-4-3 where P is the maximum output power rating 80.0 MHz to 2.5 GHz 80.0 MHz to 2.5 GHz of the transmitter in watts (W) according to the transmitter manufacturer and d is the...
Page 16
0.116 0.116 0.2333 0.01 0.368 0.3687 0.7378 1.166 1.1660 0.2333 3.687 3.6872 0.7375 11.6600 11.660 23.333 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m)can be estimated using the equation applicable to the frequency of the transmitter, where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
Connector FS-L190*D / FS-L240*D / FS-L260*D / FS-P260*D / FS-L320*D Input connector ▶ DVI fiber optic(4port LC / 1port SC) input DC INLET S-VIDEO /Y DC ON/OFF SWITCH S-VIDEO /C OPTICAL IN C-VIDEO DVI IN RED /Pr DVI OUT GREEN /Y VGA IN BLUE /Pb GPIO...
Page 23
FS-L190*DT / FS-L240*DT / FS-P260*DT input connector ▶ DVI fiber optic(4port LC / 1port SC) input DC INLET SDI OUT DC ON/OFF SWITCH S-VIDEO /Y OPTICAL IN S-VIDEO /C DVI IN C-VIDEO DVI OUT RED /Pr VGA IN GREEN /Y GPIO BLUE /Pb USB TOUCH...
Page 24
FS-L420*D / FS-L550*D Input connector ▶ DVI fiber optic input AC ON/OFF SWITCH S-VIDEO /Y AC INLET S-VIDEO /C OPTICAL IN C-VIDEO DVI IN RED /Pr DVI OUT GREEN /Y VGA IN BLUE /Pb GPIO C-SYNC/H-SYNC RS232C V-SYNC SDI IN EARTH GROUND SDI OUT ▶...
Mechanical Product Drawing 19” FS-L190*D / FS-L190*DT Dimension Front view 76.5 OSD MEMBRANE SWITCH Rear view (Installed I/O Cover) Rear view (Without I/O Cover) 4-M4X12(VESA MOUNT HOLE) 4-M4X12(VESA MOUNT HOLE) Unit : mm English - 24...
Page 26
24” FS-L240*D / FS-L240*DT Dimension Front view OSD MEMBRANE SWITCH Rear view (Installed I/O Cover) Rear view (Without I/O Cover) 4-M4X12(VESA MOUNT HOLE) 4-M4X12(VESA MOUNT HOLE) Unit : mm 25 - English...
Page 27
26” FS-L260*D Dimension Front view 99.5 55.5 OSD MEMBRANE SWITCH Rear view (Installed I/O Cover) Rear view (Without I/O Cover) 4-M4X12(VESA MOUNT HOLE) 4-M4X12(VESA MOUNT HOLE) Unit : mm English - 26...
Page 28
26” FS-L260*D(LED) / FS-P260*D(LED) Dimension Front view Rear view (Without I/O Cover) Rear view (Installed I/O Cover) Unit : mm 27 - English...
Page 29
32” FS-L320*D Dimension Front view OSD MEMBRANE SWITCH Rear view (Installed I/O Cover) Rear view (Without I/O Cover) 4-M4X12(VESA MOUNT HOLE) 4-M4X12(VESA MOUNT HOLE) 4-M6(VESA MOUNT HOLE) 4-M6(VESA MOUNT HOLE) Unit : mm English - 28...
42” FS-L420*D Dimension Front view 111.1 1024.6 55 50 OSD MEMBRANE SWITCH Rear view 10-M8(USER MOUNT HOLE) Unit : mm 29 - English...
Page 31
55” FS-L550*D Dimension Front view 1293 86.3 1213.6 36.3 OSD MEMBRANE SWITCH Rear view 6-M8(VESA MOUNT HOLE) Unit : mm English - 30...
Page 32
Control OSD Button An 8 button keypad, located in bottom right corner on the front of the display, allows the user to make adjustments to various display parameters using the On Screen Display (OSD) system. ● Power Indicating LED Normal mode (ON): Green Standby mode : Blinking Green Off mode...
Page 33
6. PLUS (+) : With the OSD deactivated, it is a Hot key for increasing contrast. With the OSD activated, enter sub menu and increases the adjustment of the selected function. 7. MINUS (-) : With the OSD deactivated, it is a Hot key for increasing contrast. With theOSD activated, it decreases the adjustment of the selected function.
Page 34
Remote button function <Notice> Remote control is available in FS-L320*D / FS-L420*D / FS-L55*D models only. 1. SOURCE : Changes the display signal source. 2. POWER : Soft power turns the monitor ON or OFF. 3. UP (▲) : With the OSD deactivated,it is a Hot key for increasing brightness. With the OSD activated, moves the cursor upward.
Page 35
GPIO There are four pins on the RJ9 GPIO connector. Each pin has a preprogrammed function assigned to it. The function is initiated when the pin is grounded. Pin 1. Primary and Secondary Swap. Pin 3. Record Indicator The record indicator is displayed in the Grounding this pin will swap the primary and secondary image.
Power management This monitor does not adhere to the VESA DPMS standard when no signal is present on the video input. Model Status LED sign Power Consumption FS-L190*D Normal mode Green on <60W Standby mode Green blinking <20W FS-L190*DT Normal mode Green on <60W Standby mode...
DSUB ANALOG / RGBS input source ADJUST 1. BRIGHTNESS A D J U S T Increases or decreases the brightness. (Range : 0~100) B R I G H T N E S S 2. CONTRAST C O N T R A S T Increases or decreases the contrast.
Page 38
SETUP 1. LANGUAGE S E T U P Changes the OSD language (8 language) L A N G U A G E E N G L I S H 2. OSD COLOR O S D C O L O R Adjusts the OSD background from white opaque to translucent.
Page 39
DVI OPTICAL / DVI DIGITAL input source ADJUST 1. BRIGHTNESS A D J U S T Increases or decrease the brightness. (Range : 0~100) B R I G H T N E S S 2. CONTRAST C O N T R A S T Increases or decreases the Contrast.
Page 40
SETUP 1. LANGUAGE S E T U P Changes the OSD language (8 language) L A N G U A G E E N G L I S H 2. OSD COLOR O S D C O L O R Adjusts the OSD background from white opaque to translucent.
Page 41
YPbPr input source ADJUST 1. BRIGHTNESS A D J U S T Increases or decreases the brightness. (Range : 0~100) B R I G H T N E S S 2. CONTRAST C O N T R A S T Increases or decreases the Contrast.
Page 42
SETUP 1. LANGUAGE S E T U P Changes the OSD language (8 language) L A N G U A G E E N G L I S H 2. OSD COLOR O S D C O L O R Adjusts the OSD background from white opaque to translucent.
Page 43
SVIDEO / CVIDEO input source ADJUST 1. BRIGHTNESS A D J U S T Increases or decreases the brightness. (Range : 0~100) B R I G H T N E S S 2. CONTRAST C O N T R A S T Increases or decreases the Contrast.
Page 44
SETUP 1. LANGUAGE S E T U P Changes the OSD language (8 language) L A N G U A G E E N G L I S H 2. OSD COLOR O S D C O L O R Adjusts the OSD background from white opaque to translucent.
Page 45
SDI input source ADJUST 1. BRIGHTNESS A D J U S T Increases or decreases the brightness. (Range : 0~100) B R I G H T N E S S 2. CONTRAST C O N T R A S T Increases or decreases the Contrast.
Page 46
SETUP 1. LANGUAGE S E T U P Changes the OSD language (8 language) L A N G U A G E E N G L I S H 2. OSD COLOR O S D C O L O R Adjusts the OSD background from white opaque to translucent.
Page 47
OSD System overview Menus Function Descriptions BRIGHTNESS Press the BRIGHTNESS botton to display the ADJUST menu or UP,DOWN hot key. Setting the brightness too high or too low will decrease the amount of visible grayscales. CONTRAST Press the CONTRAST button to display the ADJUST menu or +,- hot key. Setting the Contrast too high or too low will cause loss of some grascales.
Page 48
Menus Function Descriptions H POSITION Adjusts the Horizontal position of the image. It will return to the default state when executing AUTO ADJUST or RESET SETTINGS. V POSITION Adjusts the Verticall position of the image. It will return to the default state when executing AUTO ADJUST or RESET SETTINGS.
Page 49
Menus Function Descriptions IMAGE SETTING Saves 5 user’s settings : BRIGHTNESS,CONTRAST,BACKLIGHT,COLOR,TEMP and FILTER separately.(PRESET1,2 / USER 1,2,3) ZOOM / PAN Controls the zoom in/out of the image. 0 Step : 4 Step : 9 Step : 13 Step : 18 Step : 22 Step : 26 Step : 30 Step :...
Page 50
Menus Function Descriptions OSD DURATION Adjusts the time the OSD menu remains on the screen. RESET SETTING Resets the monitor back to factory settings.. AUTO SOURCE When AUTO SOURCE SELECT is on, the monitor will automatically search for an active MAIN SELECT input Source.
Page 51
Menus Function Descriptions SWAP Changes main window and sub window position in PIP,PBP1,PBP2. PBP1 PBP2 English - 50...
Standard Signal table PC Supported Mode Horizontal Clock Vertical Resolution Frequency Frequency Frequency (KHz) (MHz) (Hz) 640 X 350 @70Hz 25.17 31.50 70.00 720 X 400 @70Hz 28.32 31.50 70.00 640 X 480 @60Hz 31.50 25.18 60.00 640 X 480 @75Hz 37.50 75.00 31.50...
Signal connector Pin Assignments VGA (15Pin D-SUB) Pin No. Assignment Pin No. Assignment No Connection Green Ground-Sync Blue Ground Ground DDC Data DDC 5V Standby H.Sync Cable Connection check V.Sync Ground-Red DDC Clock Ground-Green Ground-Blue DVI In,Out (24Pin DVI-D) Pin No. Assignment Pin No.
Page 54
S-Video (BNC) Pin No. Assignment S-VIDEO/Y (Luma) S-VIDEO/C (Chroma) Ground RS232C (D-SUB 9Pin) Pin No. Assignment No Connection No Connection Ground No Connection No Connection No Connection No Connection SDI (BNC) Pin No. Assignment SDI IN SDI OUT Ground GPIO Pin No.
Page 55
RGBHV/RGBS/YPbPr (BNC) Assignment Pin No. RGBS Y Pb Pr Green Blue CS/HS B/Pb R/Pr H-Sync / C-Sync No Connection V-Sync No Connection Ground OPTICAL , LC Type (Matched with DDL receivers) Pin No. Assignment OPTICAL Clock OPTICAL Blue OPTICAL Green OPTICAL Red OPTICAL , SC Type (Matched with DDL receivers) Pin No.
Cleaning Instructions Precautions • Before cleaning, switch the display in stand-by position to prevent the control touch panel from being activated inadvertently by sweeping over the front filter. In stand-by position the touch panel cannot be activated by just sweeping over them. To switch the display on again, you must press the stand-by key again.
Page 65
•Klear Screen • Screen TFT (Kontakt Chemie) • Incidin Foam (Ecolab) • Microzid • Mild detergent • Isopropyl alcohol with concentration < 5% • Household bleach (generic sodium hypochlorite, solutions of 5.25% sodium hypochlorite diluted with water between 1:10 and 1:100) Do NOT use: •...
Page 66
• Zep Heavy-duty glass & all surface cleaner • Klear Screen • Screen TFT (Kontakt Chemie) • Incidin Foam (Ecolab) • Microzid • Mild detergent • Isopropyl alchohol with concentration < 5% • Household bleach (generic sodium hypochlorite, solutions of 5.25% sodium hypochlorite diluted with water between1:10 and 1:100) •...
DVI ② (Fiber) install guide (Rx) Pull out the DVI ② slot gender by loosening 2 screws on the bracket DDL(4ch LC) Rx installation Insert DDL Rx into blank DVI2 slot and fasten it by 2 screws with DDL bracket. DDL(1ch LC) Rx installation Insert DOL Rx into blank DVI2 slot and fasten it by 2 screws with DOL bracket.
Page 68
DSP/DSK (1ch SC) Rx installation Insert DSP Rx into blank DVI2 slot and fasten it by 2 screws with DSP/DSK bracket. DSL (1ch SC) Rx installation Insert DSL Rx into blank DVI2 slot and fasten it by 2 screws with DSL bracket. Please place an order to provider to get each bracket for fiber extenders Fiber extender Order code...
Page 69
Thank you for choosing our product. Service Please contact our customer service if you need any information or help with our products. Warranty One year, parts and labor ASIA FORESEESON KOREA Room404-b, Pangyolnnovalley B, Sampyeong-Dong621, Bundang-gu, Seongnam-si, Gyeonggi-do,korea Tel.+82(31)8018-0780 Fax. +82(31)8018-0786 www.fsnmed.com FORESEESON CUSTOM DISPLAY INC 2210 E.
Need help?
Do you have a question about the FS-L190 D and is the answer not in the manual?