Page 1
WIS3000 Tablet and External Interface for MTS800A Matrix Switch User’s Guide Before connecting, operating or adjusting this product, please read this instruction booklet carefully and completely.
OUTPUT MENU The WIS3000 Control Tablet from FSN Medical Technologies is a single appliance that can operate FSN’s MTS800A Medical Matrix Switch with the touch of a finger. The tablet hardware and software have been designed to easily manage several independent input/ output video systems typically found in a surgical environment.
Monitors Mount Boom or Stand IP Address Monitors 1 - 8 1 - 4 1 - 4 1 - 4 ENTER INPUT MTS800A OUTPUT MENU WIS3000 DVI-D 3G-SDI CVBS Video Sources to be Switched FSN1981 - 6/2017 English - 5...
Mounting the Tablet Dock The WIS3000 tablet can be mounted securely to a stand, boom, or arm by using the supplied VESA dock. Alternately, a fold-out stand is built into the tablet holder to allow the tablet to sit on a table, counter, or other flat surface.
Docking and Removing the Tablet As the tablet holder slides onto the VESA dock, the USB charging ports are aligned. Ports When the tablet holder Click and VESA dock are fully and correctly seated, the USB charging ports are connected, and the tab on the VESA dock will “click”...
The WIS3000 touch screen tablet and graphic user interface have been designed to work with the features available in the MTS800A Switcher. Routing live video, previewing the active strea- ming signal, and remote streaming of video to another location all require pre-configuration of IP addresses.
8 to 10 seconds. Interface Start-up After the tablet is turned on, the start-up screen appears. Before connecting WIS3000 with MTS800A the following steps must be taken: Establish Wi-Fi connection. Determine main IP address and preview stream IP address. Establish a Wi-Fi connection between the router and WIS3000 Access the tablet’s system...
Strm: 192.168.1.4 Stream IP address. The Main IP address is used for communicating commands between the interface and MTS800A. The Stream IP address is used for previewing the active video signal within the interface and to a connected PC/file server.
Connecting the Interface Press Connect. Enter the Main IP address pre- viously determined, then press Connect. The interface dashboard is displayed. The next step is to establish the preview Stream IP address connection. FSN1981 - 6/2017 English - 11...
Page 12
Connecting the Interface To establish the preview Stream IP address connection, press and hold anywhere on the preview screen area. Enter the Stream IP address previously determined, then press Apply. To preview: Step A: Tap an active input signal. Step B: Tap the preview area. The active video signal is dis- played in the preview area of the interface dashboard.
The Dashboard The dashboard is the main control interface for switching video signals. In the example below, RGB signal type has been selected, and input RGB 2 is being routed to output RGB 3. Press to select the type of video signal to be switched. Make sure video signal generating devices are connected to the IN ports, and video end points (monitors, recorders, etc.) are connected to the OUT ports.
OUTPUT Output 1 Output 2 Make sure that active input video sources and output video destinations are connected to the MTS800A system. Also make sure that the proper video signal type is selected from the green button choices. Input Input...
Presets Up to 16 switch configurations, or presets, can be saved and later recalled on MTS800A. Presets only save switch configurations. Custom button names are not saved in presets. If an input or output button name is changed, the change will be reflected in all presets.
Use this window to configure streaming for both the WIS3000 touch screen tablet and a remote PC. Each MTS800A installation has unique requirements for viewing streamed content. Specia- lized network modifications are required by, and should be set-up by, each facility’s IT deptart- ment in order to allow streaming.
Cleaning Instructions CAUTION: Before cleaning, switch the display into standby mode to prevent the tablet from being acci- dentally activated. In standby mode the touch panel Tablet cannot be accidentally activated. To switch the display on again, press the standby key. Note: The tablet is not disinfected or packed in a sterile environment.
Page 20
Thank you for choosing our product. Service Please contact our customer service if you need any information or help with our products. Warranty One year, parts and labor. EC Representative FORESEESON GmbH Industriestrasse 38a, 63150 Heusenstamm, Germany Tel. +49(0)6104-643980 FORESEESON UK Ltd. Unit 71, Barwell Business Park Leatherhead Road, Chessington, Surrey KT9 2NY, UK Tel.
Need help?
Do you have a question about the MTS800A and is the answer not in the manual?
Questions and answers