Function Key Programming; About Function Key Programming; Programming Function Keys - ADT Safewatch Pro 3000EN Installation And Setup Manual

Hide thumbs Also See for Safewatch Pro 3000EN:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

About Function Key Programming

The system provides the ability to program each of the four touchpad function keys to perform one of
12 system operations. The end user can then activate the function by simply pressing and holding the
programmed key for 2 seconds. Typical functions (listed below) include single-button arming, turning
lights on/off, or single-button paging.

Programming Function Keys

Function key programming involves:
1. Assigning the function key number and partition;
2. Selecting the desired function for that key.
Start Function Key Programming mode by pressing ✱ 57 while in Data Programming mode. The
following prompts are displayed:
PROMPT
Press Key to Pgm
0 = Q u i t
0
Partition
1
Key "A" Func
Zone 95
00

Function Key Programming

VALID ENTRIES
Function Key
Press the desired function
key, A-D.
[∗] to continue
Partition Number
1 = partition 1
2 = partition 2
3 = common partition
[∗] to continue
Define Key Function
00-12 = see list to right
[∗] to continue
Returns to key number
prompt with the next
function key letter displayed.
† System defaults to these
function key settings.
†† if Night-Stay zones are
listed in Zone List 5
EXPLANATION
Press the desired function key (A-D) you want to program.
NOTE: A key programmed as a function key is no longer
available to be used as an end-user macro key or panic key.
A
B
C
D
Enter the partition in which the function key is active.
Enter the desired function for this key, 00 to 12, from the options
listed. (00 selected for example display shown at left)
00 † = For the Function key selected, functions are pre-defined:
If A selected = Zone 95 (emerg. key, same as [1] [∗] pair)
If B selected = Zone 99 (emerg. key, same as [∗] [#] pair)
If C selected = Zone 96 (emerg. key, same as [3] [#] pair)
If D selected = Single-button paging
01 = Single-button paging
02 = Display time
03 = Arm AWAY
(reports as User 00 if closing reports are enabled)
04 = Arm STAY
(reports as User 00 if closing reports are enabled)
05 = Arm NIGHT-STAY
06 = Step Arming
(arms STAY, then NIGHT-STAY
07 = Output Device control
operation type 66–function key in *80 Menu Mode)
08 = Communication Test
09 = Macro Key 1
(define macro by user code + [#] [6] [6] command)
10 = Macro Key 2
(define macro by user code + [#] [6] [6] command)
11 = Macro Key 3
(define macro by user code + [#] [6] [6] command)
12 = Macro Key 4
(define macro by user code + [#] [6] [6] command)
S E C T I O N
( ∗ ∗ ∗ ∗ 57 Menu Mode)
1
2
3
OFF
AWAY
STAY
4
5
6
TEST
BYPASS
7
8
9
INSTANT
CODE
CHECK
0
#
*
READY
(sends a 999-9999 message to pager)
(reports as User 00 if closing reports enabled)
††
, then AWAY)
(for device programmed as system
(sends Contact ID code 601)
8
8-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enterpreneur 3000enSecurity manager 3000en