ADT Safewatch Pro 3000EN Installation And Setup Manual page 52

Hide thumbs Also See for Safewatch Pro 3000EN:
Table of Contents

Advertisement

3000EN Series: Installation Instructions
PROMPT
Zn ZT P RC
In: L
10 00 1 10
RF: 1
OR
Zn ZT P RC
In: AD
10 00 1 10
AW: 07
OR
Zn ZT P RC
HW: RT
10 00 1 10
EL
1
10 Zone Type
Perimeter
03
10 Partition
1
10 Report Code
1st 01 2nd 00 10
02 HARDWIRE TYPE
EOL
0
02 Response Time
1
5-2
VALID ENTRIES
Summary Screen
[∗] to continue
Zone Type (ZT)
(see table at right; types
92/93 only programmable
via downloader)
Partition No. (P)
1-3 = partition (3 = common)
[∗] to continue
Report Code (RC)
First Digit:
01 † = enable CID report
00 = disable CID report
Second Digit: entries
ignored
[∗] to continue
Hardwire Type
0 = EOL
1 = NC
2 = NO
[∗] to continue
Response Time (RT)
0 = 10mSec
1 = 350mSec
2 = 700mSec
3 = 1.2 seconds
[∗] to continue
EXPLANATION
A summary display appears.
"IN: L" appears for wireless zones and indicates input type
and loop.
"IN: AD" appears for hardwire expansion zones (AW) and
indicates the module's address (AD), which is based on the
zone number.
"HW: RT" appears for hardwire zones and indicates
configuration (EOL, NO, NC ) and response time selection.
Each zone must be assigned to a zone type, which defines the
way in which the system responds to faults in that zone.
Enter the Zone Type code from the list below:
Note: If 00 is entered, Delete Zone ? will be displayed.
00 = Not used
07 = 24-Hr Audible
01 = Entry/exit #1
08 = 24-Hr Aux
02 = Entry/exit #2
09 = Fire
03 = Perimeter
10 = Interior w/Delay
04 = Interior Follower
12 = Monitor Zone
05 = Trouble Day/Alarm Night 14 = Carbon Monoxide 25 = 24-Hr Non-Alarm
06 = 24-Hr Silent
16 = Fire w/Verify
*5800 button-type transmitters only
Enter the Partition number for this zone. Partition 1 is shown
entered.
Entering any non-zero entry as the first digit enables the
Contact ID report code for this zone. Refer to the System
Communication section for information about report codes
and formats.
† typical entry
This prompt appears only for zone numbers 02-08.
Zone 1 is automatically set for EOL operation.
This prompt appears only for hard-wired zones 01-08 (zone 02
is used as an example in display).
20 = Arm–STAY*
21 = Arm–AWAY*
22 = Disarm*
23 = No Alarm Resp
24 = Silent Burglary
77 = Keyswitch
81 = AAV Monitor Zone
90-93 = Configurable