Serial Control

Status Read Command

Format
The command is sent from PC to the projector with the
format below;
'CR' [Command] 'CR'
Command: one character (refer to the command table
below.
The projector decodes the command and returns the
'Character string' with the format below;
command
Function
CR0
Status Read
CR6
Temperature Read
The tables on this page and previous page show the typical command lists for controlling the projector. Please
consult your local dealer for further information of other commands.
Projector
return
Power On
00
Stand-by mode
80
Countdown
40
Cooling down
20
Power Malfunction
10
Cooling down at the temperature anomaly
28
Unable to receive the RC232C command.
02
Cooling down at Power Management mode
24
Power Management mode after Cooling down
04
Cooling down after the projector is turned off when the lamps
21
are out.
Stand-by mode after Cooling down when the lamps are out.
81
Stand-by mode after Cooling down at the temperature
88
anomaly.
Cooling down when the projector is turned off by the shutter
2C
management function.
Stand-by mode after Cooling down by the shutter management
8C
function.
S1 = Temperature at Sensor 1 (TempA)(˚C)
S2 = Temperature at Sensor 2 (TempB)(˚C)
S3 = Temperature at Sensor 3 (TempC)(˚C)
S4 = Temperature at Sensor 4 (TempD)(˚C)
S1 S2 S3 S4
(ex.) S1 = 12.3˚C, S2 = 23.4˚C, S3 = 34.5˚C, S4 = 40.5˚C
--> The projector displays "12.3 23.4 34.5 40.5"
( For each sensor, two digit and the tenth place numbers are
displayed with a space between each temperature.)
Communication failure
?