Sanyo PDG-DHT8000L Service Manual page 51

Sanyo multimedia projector service manual
Hide thumbs Also See for PDG-DHT8000L:
Table of Contents

Advertisement

Electrical Adjustment
Grp / No.
Item
1
Dither Enable
2
VSBEG
3
Field Sense Invert Enable
204
Simulation mode
0
PW392C Enable
1
PW610 Enable
205
Spread Spectrum
0
Enable
1
Spread Rate
2
Spread Frequency
210
Lamp Control
0
Dimmer SW
1
Manual Control
2
DIMMER_CTRL_LEVEL1
3
DIMMER_CTRL_LEVEL2
4
DIMMER_CTRL_LEVEL3
5
DIMMER_CTRL_LEVEL4
6
DIMMER_CTRL_LEVEL5
7
DIMMER_CTRL_LEVEL6
8
DIMMER_CTRL_LEVEL7
9
DIMMER_CTRL_LEVEL8
10
DIMMER_CTRL_LEVEL9
11
DIMMER_CTRL_LEVEL10
12
DIMMER_CTRL_LEVEL11
13
DIMMER_CTRL_LEVEL12
14
DIMMER_CTRL_LEVEL13
15
DIMMER_CTRL_LEVEL14
16
DIMMER_CTRL_LEVEL15
17
DIMMER_AVERAGE_POINT
18
DIMMER_AVERAGE_DATA
19
DIMMER_LEVEL_AUTO
20
DIMMER_LEVEL_NORMAL
21
DIMMER_LEVEL_ECO
23
VOLTAGE_LEVEL
24
DIMMER_LEVEL_HIGH
220
Projector Error Log
0
Warning_Log_1
:
:
49
Warning_Log_50
50
Warning_Log Reset
235
Shutter
0
PRE_MOTION
1
CMP_TRM
2
OUT_DLY_TRM
3
CMP_CHK_CNT
4
OPEN_DLY
5
CLOSE_DLY
6
Position Check Time
7
Stop Mode
8
Enable Close Cmd
10
Sutter Management Upper Time
236
Lamp Mode Switch
0
2 Lamp Mode
1
Lamp1 Mode
2
Lamp2 Mode
240
Flow Calibration
0
Flow Calibration Exe *
Function
0: Disable 1: Enable
0: Disable 1: Enable
0: Off, 1: On
0: Off, 1: On
0:Auto 1:Manual
Lamp Power Manual Control (DIMMER_CTRL_LEVEL
0(Dark)~15(Bright))
Y Level1 Data for Dimmer
Y Level2 Data for Dimmer
Y Level3 Data for Dimmer
Y Level4 Data for Dimmer
Y Level5 Data for Dimmer
Y Level6 Data for Dimmer
Y Level7 Data for Dimmer
Y Level8 Data for Dimmer
Y Level9 Data for Dimmer
Y Level10 Data for Dimmer
Y Level11 Data for Dimmer
Y Level12 Data for Dimmer
Y Level13 Data for Dimmer
Y Level14 Data for Dimmer
Y Level15 Data for Dimmer
Y Average Point
Y Average Data (Read only)
Current Y Level (Read only)
Dim Level at Normal
Dim Level at Eco
Lamp Voltage (Read only)
Dim Level at High
Latest Error log
:
50th Error log
Log is cleared when the value is set to 10.
Shutter Warm - up Operation (0: Yes, 1: No)
Chattering Detecting Term
Output Term
Count of Information Sync
Open Output Delay
Close Output Delay
Position Check Time
Shutter Operation in Stop Mode
0:Free, 1:Brake
Shutter Close Command
0:Disable, 1:Enable
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
Range
0 - 1
0 - 15
0 - 1
0 - 1
0 - 1
0 - 1
0 - 300
0 - 500
0 - 1
0 - 15
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 16
-
-
0 - 15
0 - 15
-
0 - 15
0 - 32767
:
0 - 32767
0 ~ 10
0 - 1
0 - 32767
0 - 32767
0 - 15
0 - 63
0 - 63
1 - 255
0 - 1
0 - 1
180 - 999
0 - 99
0 - 99
0 - 99
0 - 1
-51-
Initial
Note
1
2
0
0
0
1
100
150
0
0
7
14
21
28
35
42
49
56
63
70
77
84
91
98
105
4
-
-
15
0
-
15
0
:
0
0
Initial: 1 / Shipping: 0
7000
15000
5
30
30
20
1
1
480
0
0
0
0

Hide quick links: