Rinnai RU80i Installation And Operation Manual page 17

Direct vent tankless water heater
Hide thumbs Also See for RU80i:
Table of Contents

Advertisement

Available languages

Available languages

Isola on Valves and Pressure Relief Valve  
The isola on valves provide the ability to isolate the 
water heater from the structure's plumbing and allow 
quick access to flush the heat exchanger.  Check with 
local codes to determine if a pressure and 
temperature relief valve is required.  The included 
valves meet American Na onal Standard (ANSI
Z21.10.3) / Canadian Standard (CSA 4.3) and are 
ANSI/NSF 61 approved for potable water. 
Isola on Valves Installa on Instruc ons: 
1.  Wrap the ends of the threaded water inlet & 
outlet on the tankless water heater, as well as 
the threaded end of the approved pressure relief 
valve  with a minimum of 5 wraps of Teflon® 
tape. 
2.  Screw the pressure relief valve into the 3/4" 
threads opposite the wing handle on the HOT 
water service valve. (RED drain handle) (see 
Pressure Relief Valve Sec on for proper 
installa on requirements) 
3.  Loosen the 3/4" union nut on the HOT water 
valve and connect to the HOT water outlet on 
the tankless water heater. If nut is removed, 
ensure that you realign the tailpiece accurately 
to the valve and that the black washer is 
posi oned such that the raised metal edge of 
the valve is inside the washer. 
4.  Align the direc on of the HOT water drain to the 
desired posi on. 
5.  Tighten the union assembly to the HOT water 
valve using approximately 15 foot lbs of torque. 
6.  Repeat steps 3‐5 for the COLD water valve. 
(BLUE drain handle) for connec on to the COLD 
water inlet on the tankless water heater. 
7.  Connect the INLET on the COLD water valve to 
the MAIN SOURCE of the water supply. 
8.  Connect the OUTLET on the HOT water valve to 
the HOT WATER plumbing system. 
9.  Ensure that both drain valve lever handles are in 
the closed posi on (perpendicular to the drain 
por on of the body). 
 
A  Pressure Relief Valve (PRV) 
B  PRV Discharge Outlet 
C  Hot Ball Valve Drain Handle 
D  Cold Ball Valve Drain Handle 
Pressure Relief Valve Installa on Instruc ons: 
The PRV must be connected by the threaded 
connec on opposite the wing handle on the hot 
water valve (designated by the RED drain handle) or 
the threaded connec on on the side of the reloca on 
fi ng above the hot water valve. Installa on must 
maintain a ¾" port size with no shut off valve or line 
restric on in‐between the appliance and the PRV. The 
discharge line from the PRV should pitch downward 
and terminate 6" above drains where discharge will 
be clearly visible. The discharge end of the line shall 
be plain (unthreaded) and a minimum of ¾" in 
diameter. The discharge line material must be 
suitable for water at least 180° Fahrenheit and can be 
no more than 30 feet in length and contain no more 
than 4 elbows or bends. No valve of any type may be 
installed in the discharge line of the pressure relief 
valve. 
Pressure Relief Valve Maintenance: 
For proper care of this approved pressure relief valve, 
it is recommended that the valve is manually 
operated once a year. In doing so, it will be necessary 
totake precau ons with regard to the discharge of 
poten ally scalding hot water under pressure. Ensure 
discharge has a place to flow. Contact with your body 
or other property may cause damage or harm. 
Please note that only the PRV in this package is 
cer fied by CSA Interna onal as an approved item. 
KB Series Manual 