Electrical Alignment; Preparation - Sony RM-B750 User Manual

Remote control unit rm-b750
Hide thumbs Also See for RM-B750:
Table of Contents

Advertisement

2-1. Preparation

Measuring Equipment
. Waveform monitor/Vectorscope Tektronix 1780R (for NTSC)/1781R (for PAL) or equivalent
. Color monitor
Peripheral Equipment
. BVP-E10 + CA-530/570/950, or
HDC-950/930
(The video output should be present at the remote connector.)
. AC adaptor AC-550/550CE, or DC variable power supply
Connection
COLOR VIDEO CAMERA
CAMERA ADAPTOR
REMOTE
*
DC IN
AC ADAPTOR
AC-550/550CE
or DC variable
power supply
If using a DC variable power supply to drive power, connect the positive (+) side of the power supply to
pin 4 of the DC IN connector on the camera adaptor, and negative (_) side to pin 1.
n
When the power is supplied via the DC IN connector, be sure to press the micro switch on the DC IN
connector, that turns on the power. It is recommended to use an XLR plug when driving power via the
DC IN connector.
Initial settings
. PANEL ACTIVE button/Operation panel : ON (lit)
. Test signal select button/Operation panel : BARS
. CABLE COMP SELECT
*1 : To select the cable length, use the menu of this unit. For details, refer to the operation manual supplied with the unit.
RM-B750
Section 2

Electrical Alignment

BVP-E10 series
CA-570/530 series
REMOTE CABLE
(supplied with
RM-B750,10 m)
*
Micro switch
_
*1
:
10 m
PANEL
STANDARD
TEST
BARS
CLOSE
VTR
ACTIVE
START/STOP
MEMORY
MONITOR
STICK
AWB
ABB
WHITE
MONITOR
FUNCTION
VF DISP
BLACK
MAINTENANCE
VF MENU
SCENE
CANCEL
AUTO
IRIS/MB
IRIS
ACTIVE MASTER
BLACK
PAINT
ENTER
EXT
IRIS
ALARM
MENU SELECT
REMOTE CONTROL UNIT RM-B750
REMOTE
75 Z
CONTROL UNIT
RM-B750
1
4
+
2
3
Waveform monitor/
Vector scope
A-ch
PIX
Color monitor
75
Z
2-1 (E)