Wiring your CW-80 Transformer

C
onnect your FasTrack terminal section to the CW-80 Transformer. Use the wires that are
already attached to the terminal section. Make sure that all connections are secure. Loose
connections can produce extremely high temperatures. For this reason, do not touch the
terminals or track connections during use. Also, do not locate scenery materials such as
lichen or ground foam near the terminals.
1. Feed the wires through the notch in the FasTrack terminal section. Refer to
Figure 4 on page 8.
2. Loosen the red TRACK thumbscrew terminal, then slide the spade-shaped
connector at the end of the red wire into position. The thumbscrew post
should be positioned between the "blades" of the spade connector. Be sure that the blades
are touching the metal post. Tighten the thumbscrew to secure the connection.
3. Loosen the black TRACK thumbscrew terminal, then slide the spade-shaped
connector at the end of the black wire into position. Tighten the thumbscrew to
secure the connection. Be sure that the blades are touching the metal post. Tighten the
thumbscrew to secure the connection.
4. If you need to power an accessory (available separately at your
authorized Lionel dealer), connect the accessory to the ACCESSORY
thumbscrew terminals. Use the accessory wire included with the CW-80 Transformer.
5. Plug the CW-80 Transformer into your wall outlet (120 volts).
As your layout expands, you may also make power connections with the stripped ends of
wires, placing no more than two wires on each terminal. For best performance on large
layouts, it is recommended that you use 16-gauge wire to connect your CW-80 Transformer to
the track. On larger layouts where several track connections are required, the use of separate
junctions/terminal strips (available at your local electronics store) is recommended to
prevent voltage drops.
To prevent the excessive build up of heat, be sure to select the proper wire gauge
Caution!
for your layout. Follow these guidelines:
• Track connections must be made with 18-gauge wire or heavier. Larger
layouts require a minimum of 16-gauge wire.
• Use 24-gauge wire only when connecting single accessories that require lower
current.
• When wiring multiple accessories (two or more) or accessories that require
higher current, be sure to use 18- to 16-gauge wire.