Advertisement

5
4. RS-232C command for module microcomputer
Command
Name
A
∗∗∗
ABL
ABL ADJUSTMENT
AMT
S00
AUDIO MUTE OFF
S01
AUDIO MUTE ON
APW
S00
APL WB FUNCTION:OFF
S01
APL WB FUNCTION:ON
B
∗∗∗
BAL
BALANCE ADJUSTMENT
∗∗∗
BAS
BASS ADJUSTMENT
BCP
BACKUP COPY
C
CBU
CLEAR BACKUP
CHM
CLEAR HOUR METER
CPC
CLEAR POWER ON COUNT
CPD
CLEAR POWER DOWN
CPM
CLEAR PLUSE METER
CSD
CLEAR SHUT DOWN
D
DRV
S00
DRIVE OFF
S01
DRIVE ON
E
ESV
S00
POWER CONTROL NORMAL Setting Power Consumption mode to 4-split normal curve
S01
POWER CONTROL MODE1
S02
POWER CONTROL MODE2
S10
POWER CONTROL NORMAL Setting Power Consumption mode to 4-split normal curve (domestic)
S11
POWER CONTROL MODE1
S12
POWER CONTROL MODE2
F
FAJ
FINISH ADJUSTMENT
FAN
FACTRY NO
FAY
FACTRY YES
FCS
S00
FOCUS OFF
S01
FOCUS ON
M
MKC
S00
MASK COMBINATION OFF
S01
MASK COMBINATION 01
S02
MASK COMBINATION 02
S03
MASK COMBINATION 03
S04
MASK COMBINATION 04
S05
MASK COMBINATION 05
S06
MASK COMBINATION 06
S07
MASK COMBINATION 07
S08
MASK COMBINATION 08
S09
MASK COMBINATION 09
MKS
S00
MASK SINGLE OFF
S01
MASK SINGLE 1
S02
MASK SINGLE 2
S03
MASK SINGLE 3
S04
MASK SINGLE 4
5
6
Function
Adjusting the upper limit of the power
Turning off the audio muting
Turning on the audio muting
WB correction interlocked with APL: OFF
WB correction interlocked with APL: ON
Audio balance adjustment
Audio bass adjustment
Copying the backup data in the EEPROM
Clearing backup data
Clearing data of the hour meter
Clearing power-on count data
Clearing power-down information
Clearing data of the pulse meter
Clearing shutdown information
Main power off
Main power on
Setting Power Consumption mode to 2-split normal curve
Setting Power Consumption mode to 2-split power-saving curve
Setting Power Consumption mode to 2-split normal curve (domestic)
Setting Power Consumption mode to 2-split power-saving curve (domestic)
Determining the flag of the HD DIGITAL Assy adjustment in "adjustment is completed"
Entering Factory mode
Turning the FOCUS function off
Turning the FOCUS function on
MASK off
H ramp (slant 1) M
H ramp (slant 4) M
Slanting ramp M
30 for aging
05 for aging
Erasing afterimage 1
Erasing afterimage 2 (RGB: zigzag, V: reverse)
White (change in luminance level)
PEAK SEEK RASTER
MASK OFF
H ramp (slant 1)
H ramp (slant 4)
V ramp (slant 1)
Slanting ramp
PDP-506PE
6
7
Effective only in
Factory mode
?
?
?
?
?
?
Used only when the panel is replaced
?
Used only when the power unit is replaced
?
Used only when the panel is replaced
?
Used only when the panel is replaced
?
Used only when the panel is replaced
?
?
Turning the mask setting off
?
?
?
?
?
?
?
?
?
?
?
?
?
7
8
A
Remarks
B
C
D
E
F