Diagnosis Of Shutdown/Power-Down Indicated By Leds; Power/Shut Down Count - Pioneer PDP-506PE Service Manual

Plasma display
Hide thumbs Also See for PDP-506PE:
Table of Contents

Advertisement

5

7.1.2 DIAGNOSIS OF SHUTDOWN/POWER-DOWN INDICATED BY LEDS

• Operation statuses indicated by LEDs
Status
Standby
1
Lit in Red
2
Lit in Blue
Power ON
Red flashes
AC Power OFF of
3
(1000ms)
one side
Red and
System cable
4
blue flash
disconnection
(1000ms)
Red flashes
5
Power-down
(500+2500ms)
Blue flashes
6
Shutdown
(500+2500ms)
Lit in Red and
No backup copy
7
blue flashes
(200ms)
• PD (power-down) count
1
Not used
2
POWER SUPPLY Unit
3
SCAN Assy
4
5V power supply for SCAN
5
Y-DRIVE (Not used)
6
DCDC for Y drive
7
Y-SUS
8
ADDRESS Assy
9
X-DRIVE
10
DCDC for X drive
11
X-SUS
12
Not used
13
Sequence drive stop
14
Not used
15
UNKNOWN
Note:
• When a shutdown occurs, a warning will be issued by the
Media Receiver and displayed, then the power will be shut off.
• When a shutdown or power-down occurs on the Panel side,
the Media Receiver will enter Standby mode (the red LED
will light).
5
6
LED Pattern
Blue
Red
Blue
Red
Blue
Red
1000ms
Blue
1000ms
Red
1000ms
Blue
Once
Twice
Red
500ms
Blue
500ms
Red
Once
Twice
200ms
Blue
Red
: Lit in Red LED
: Lit in Blue LED
• SD (shut down) count
* When a jumper (J105) between the HD AUDIO Assy and
the POWER SUPPLY Unit is disconnected, the SD LED
flashes five times in this manner.
PDP-506PE
6
7
n times
2.5s
n times
2.5s
1
SEQUENCE PROCESSOR (SQ_IC)
2
MDU-IIC
3
RST2 abnormality
4
Panel high temperature
5
Speaker short-circuit *
7
8
A
B
Once
Once
C
D
E
F
63
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-506puPdp-436pePdp-436pu

Table of Contents