Pioneer PDP-506PE Service Manual page 52

Plasma display
Hide thumbs Also See for PDP-506PE:
Table of Contents

Advertisement

1
A
7 Acquisition of ABL/WB adjustment data • • • [QPW]
The command QPW is for acquiring data on the panel's factory-preset items whose memory tables are changed in
sequence.
Command
Effective Operation
Format
[QPW]
All operations
Data Arrangement
B
ECO
1
Drive sequence
2
Standard/nonstandard
3
Type of ABL/WB tables
4
ABL adjustment value
5
R-HIGH adjustment value
6
G-HIGH adjustment value
7
B-HIGH adjustment value
8
R-LOW adjustment value
C
9
G-LOW adjustment value
10
B-LOW adjustment value
11
Gamma setting
12
Streaking correction
13
Peripheral luminance correction
14
Reservation
15
WB interlocked with APL
16
Transition of protective operations
17
Reservation
D
CS
7 Acquisition of parameters • • • [QPM]
The command QPM is for acquiring the accumulated number of pulses for each of 5 blocks from the EEPROM.
Command
Effective Operation
Format
[QPM]
All operations
E
Data Arrangement
ECO
1
Pulse meter B 1
2
Pulse meter B 2
3
Pulse meter B 3
4
Pulse meter B 4
5
Pulse meter B 5
CS
F
• The output data on the accumulated number of pulses for each block are calculated in the following way: the high-order 4
bytes of the accumulated number of pulses for each block are converted into a decimal number, and the high-order 8
digits are transmitted. The unit of each block is M_pulse (mega).
52
1
2
Modes
To acquire data on operations of the panel Return data: 3 (ECO)+35(DATA)+2(CS)=40Byte
Output
Data
Example
Length
3Byte
QPW
3Byte
60V
1Byte
S
2Byte
T2
3Byte
128
3Byte
256
3Byte
256
3Byte
256
3Byte
512
3Byte
512
3Byte
512
1Byte
A
1Byte
1
1Byte
0
1Byte
1Byte
0
1Byte
0
∗∗
2Byte
2Byte
37
Modes
To acquire data on operations of the panel Return data: 3 (ECO)+40(DATA)+2(CS)=45Byte
Data
Output Example
Length
3Byte
QPM
8Byte
00000000
8Byte
00000000
8Byte
00000000
8Byte
00000000
8Byte
00000000
2Byte
E7
2
3
Function
¶ Drive sequence
48V Video48 Hz
50V Video50 Hz
60V Video60 Hz
72V Video72 Hz
75V Video75 Hz
60P PC60Hz
70P PC70Hz
¶ Standard/
nonstandard
S
Standard
N
Nonstandard
¶ Gamma setting
n
0 to F
Function
PDP-506PE
3
4
Remarks
¶ Setting for Items 12 and 15
0
OFF
1
ON
¶ Peripheral luminance
correction
0
OFF
2
ON (interlocked with APL)
¶ Transition of brightness by
protective operations
0
Upper limit state for brightness
1
Brightness being reduced
2
Lower limit state for brightness
3
Brightness being increased
¶ Type of ABL/WB tables