Therefore, the following checks should be performed for the continued protection of the customer and servicetechnician. PDP-506PE...
Page 3
PRODUCT SAFETY NOTICE With the AC plug removed from an AC power source, place a Many electrical and mechanical parts in PIONEER set have jumper across the two plug prongs. Turn the AC power switch on. special safety related characteristics. These are often not evident...
Page 4
50 SCAN B Assy 50 Y DRIVE Assy POWER SUPPLY Unit 50 X DRIVE Assy SUS CLAMP 1 Assy 50 SCAN A Assy AC Inlet SUS CLAMP 2 Assy Power Switch (S1) Fig.1 Charged Section and High Voltage Generating Point (Rear View) PDP-506PE...
Page 5
To protect products from damages or failures during transit, the shipping mode should be set or the shipping screws should be installed before shipment. Please be sure to follow this method especially if it is specified in this manual. PDP-506PE...
7.1.5 POWER ON/OFF FUNCTION FOR THE LARGE-SIGNAL SYSTEM ..........76 7.1.6 BACKUP WHEN THE MAIN UNIT IS ADJUSTED ................77 7.1.7 HOW TO CLEAR HISTORY DATA ..................... 79 7.1.8 DISASSEMBLY..........................81 7.2 IC ................................85 8. PANEL FACILITIES ............................94 PDP-506PE...
For the applying amount of lubricants or glue, follow the instructions in this manual. (In the case of no amount instructions, apply as you think it appropriate.) 2.1 PACKING SECTION PDP-506PEonly PDP-506PE only PDP-506PE only PDP-506PE...
Page 9
See Contrast table (2) Mirror Mat See Contrast table (2) Caution Card See Contrast table (2) (2) CONTRAST TABLE PDP-506PE/WYVI and PDP-506PU/KUCXC are constructed the same except for the following: Mark No. Symbol and Description PDP-506PE/WYVI PDP-506PU/KUCXC > 1 Power Cord...
2.2 REAR SECTION PDP-506PE only To Power Switch Refer to "2.3 FRONT SECTION". PDP-506PE...
Page 11
Screw PMZ26P060FTB Screw BPZ30P080FTB Screw AMZ30P060FTB Screw TBZ40P080FTB (2) CONTRAST TABLE PDP-506PE/WYVI and PDP-506PU/KUCXC are constructed the same except for the following: Mark No. Symbol and Description PDP-506PE/WYVI PDP-506PU/KUCXC 6 Model Label (506PE) AAL2661 Not used 6 Model Label (506PU)
2.3 FRONT SECTION Refer to "2.4 CHASSIS SECTION (1/2)", PDP-506PE only PDP-506PE...
Page 13
Insulation Sheet B AED1284 Power Display Label (506) See Contrast table (2) Screw Rivet AEC1877 (2) CONTRAST TABLE PDP-506PE/WYVI and PDP-506PU/KUCXC are constructed the same except for the following: Mark No. Symbol and Description PDP-506PE/WYVI PDP-506PU/KUCXC 9 Power Display Label (506) AAX3217...
2.5 CHASSIS SECTION (2/2) To HD LED CN1671 HD IR CN1681 Power Switch PDP-506PE...
Page 17
Screw PMB30P060FTC 3P Housing Wire (J113) See Contrast table (2) Screw VBB30P080FNI (2) CONTRAST TABLE PDP-506PE/WYVI and PDP-506PU/KUCXC are constructed the same except for the following: Mark No. Symbol and Description PDP-506PE/WYVI PDP-506PU/KUCXC 1 50 X DRIVE Assy AWW1075 AWW1020 or AWW1075...
Page 21
÷ When ordering service parts, be sure to refer to "EXPLODED VIEWS and PARTS LIST" or "PCB PARTS LIST". ÷ The > mark found on some component parts indicates the importance of the safety factor of the part. Therefore, when replacing, be sure to use parts of identical designation. PDP-506PE...
V+ADR5 V+ADR4 V+ADR3 V+ADR2 V+ADR1 CLK/LE/HBLK/LBLK CLK/LE/HBLK/LBLK R/G/B R/G/B IC1555 IC1554 IC1553 IC1552 IC1551 IC1555 IC1554 IC1553 IC1552 IC1551 Driver IC Driver IC Driver IC Driver IC Driver IC Driver IC Driver IC Driver IC Driver IC Driver IC PDP-506PE...
V+ADR5 V+ADR4 V+ADR3 V+ADR2 V+ADR1 CLK/LE/HBLK/LBLK CLK/LE/HBLK/LBLK R/G/B R/G/B IC1555 IC1554 IC1553 IC1552 IC1551 IC1555 IC1554 IC1553 IC1552 IC1551 Driver IC Driver IC Driver IC Driver IC Driver IC Driver IC Driver IC Driver IC Driver IC Driver IC PDP-506PE...
Scan IC IC2805 Scan IC IC2806 Scan IC CN2802 Serial Data CN2702 IC2701 Scan IC IC2702 Scan IC IC2703 Scan IC IC2704 Scan IC IC2705 Scan IC PSUS IC2706 IC5V Scan IC 50 SCAN A ASSY Scan Signal (LOWER) PDP-506PE...
LVDS V+8V LVDS FIELD IC3301 H DET Flash Memory AUDIO L DCLK, DE RA, GA, BA AUDIO R SCL, SDA SCL, SDA A_MUTE,A_STBY_B IC3001 A_NG TMDS Receiver Bus Buffer Bus Buffer V+3V STB TMDS STB_MT MDR CONNECTOR DVI CONNECTOR PDP-506PE...
V : 1V/div H : 200nsec/div CH4 : IC1555-pin 14 (LE) V : 1V/div H : 200nsec/div CH5 : IC1555-pin 19 (HBLK) V : 1V/div H : 200nsec/div CH6 : IC1555-pin 17 (LBLK) V : 1V/div H : 200nsec/div PDP-506PE...
Page 32
V : 50V/div H : 5µsec/div (Y DRIVE Assy) CH4 : K2006 (SOFT-D) - K2002 (GND_D) V : 1V/div H : 2msec/div (Y DRIVE Assy) CH5 : K2023 (YPR-U) - K2002 (GND_D) V : 1V/div H : 2msec/div (Y DRIVE Assy) PDP-506PE...
Ex.2 When there are 3 effective digits (such as in high precision metal film resistors). 5.62k Ω 562 x 10 5621 RN1/4PC 5 6 2 1 7 7 7 7 LIST OF WHOLE PCB ASSEMBLIES PDP-506PE PDP-506PU Mark Symbol and Description /WYVI /KUCXC 1..PANEL CHASSIS (506) ASSY...
7 7 7 7 PCB PARTS LIST FOR PDP-506PE/WYVI UNLESS OTHER WISE NOTED Mark No. Description Part No. Mark No. Description Part No. CAPACITORS 50 ADDRESS ASSY C2701,C2711,C2721 (0.1U/250V) ACG1088 [50 ADR LOGIC BLOCK] C2731,C2741,C2751 (0.1U/250V) ACG1088 SEMICONDUCTORS C2710,C2720,C2730,C2740,C2750 CCSRCH181J50...
Page 40
KN3752 WRAPPING TERMINAL VNF1084 [ST TERMINAL BLOCK] COILS AND FILTERS > L3901,L3902 LINE FILTER ATF1206 CAPACITORS > C3906,C3908,C3914,C3916 CCSRCH101J50 C3903,C3911 CKSRYB332K50 C3904,C3912 CKSRYF473Z50 RESISTORS R3901-R3904 RD1/2MMF100J OTHERS JA3901 SPEAKER TERMINAL AKE1061 POWER SUPPLY UNIT POWER SUPPLY Unit has no service part. PDP-506PE...
The assembly must be replaced as a unit, and no part POWER SUPPLY Unit replacement is allowed. HD DIGITAL Assy No adjustment required 50 X DRIVE Assy No adjustment required 50 Y DRIVE Assy No adjustment required Other assemblies No adjustment required PDP-506PE...
6.2 RS-232C COMMAND • The panel control items for the PDP-506PE, PU / PDP-436PE, PU systems can be controlled with the RS-232C commands by connecting a PC through the GGF1475 special communication device when the Media Receiver is not connected with the PDP.
Page 43
Example of communication: If an adjustment command that gives an adjustment value out of the adjustable range is sent MR / External PC Returns from the PDP Adjustment Adjustment Command Command Value 0x02 0x03 ∗∗ 0x02 0x03 7 Error process If an error is generated between STX and ETX, a return signal will not be issued. PDP-506PE...
Page 44
• Checksum (CS): A checksum is used for judging if any error exists in the data sent back from the panel. If an error is detected, it is possible to resend the QUEST command from the MR / External PC to try to acquire data again. PDP-506PE...
Page 45
White (change in luminance level) MASK COMBINATION 09 PEAK SEEK RASTER MASK SINGLE OFF MASK OFF MASK SINGLE 1 H ramp (slant 1) MASK SINGLE 2 H ramp (slant 4) MASK SINGLE 3 V ramp (slant 1) MASK SINGLE 4 Slanting ramp PDP-506PE...
Page 46
Red 1023 + α MASK SINGLE 68 Green 1023 + α MASK SINGLE 69 Blue 1023 + α MASK SINGLE 70 Red 588 + α MASK SINGLE 71 Green 588 + α MASK SINGLE 72 Blue 588 + α MASK SINGLE 73 PDP-506PE...
Page 47
Measures against AM radio noise - Pattern 4 SUS FREQUENCY MODE5 Measures against AM radio noise - Pattern 5 SUS FREQUENCY MODE6 Measures against AM radio noise - Pattern 6 SUS FREQUENCY MODE7 Measures against AM radio noise - Pattern 7 PDP-506PE...
Page 48
S00 WB INITIALIZE NO Panel WB standard output mode: off S01 WB INITIALIZE YES Panel WB standard output mode: on ∗∗∗ X-SUS-B ADJ X-SUS-B ADJ ∗∗∗ Y-SUS-B ADJ Y-SUS-B ADJ ∗∗∗ Y-SUSTAIL ADJ Y-SUSTAIL ADJ ∗∗∗ Y-SUSTAIL W AJD Y-SUSTAIL W AJD PDP-506PE...
Page 49
When the program is only for another unit (for MDUcom) 5th character Fixed 6th character Reservation 7th character Reservation 8th character Reservation • For the version indication, the bytes reserved for special use must be replaced with spaces if they are not used. PDP-506PE...
Page 50
MASK-OFF Y-SUS Adjustment completed MASK-ON ADRS Adjustment not ¶ SD subdata (IIC) completed X-DRV No SD subdata X-DCDC EEPROM X-SUS ¶ Adjustment-data BACKUP backup Not used SQ-IC With backup data VOL IC Not used No data Specification inability PDP-506PE...
Page 51
V-OFT adjustment value 3Byte V-RST-P adjustment value 3Byte XSB adjustment value 3Byte YSB adjustment value 3Byte YTG adjustment value 3Byte YTW adjustment value 3Byte RSW adjustment value 3Byte R-RIVISE setting value 1Byte G-RIVISE setting value 1Byte B-RIVISE setting value 1Byte 2Byte PDP-506PE...
Page 52
• The output data on the accumulated number of pulses for each block are calculated in the following way: the high-order 4 bytes of the accumulated number of pulses for each block are converted into a decimal number, and the high-order 8 digits are transmitted. The unit of each block is M_pulse (mega). PDP-506PE...
Page 53
Seventh latest "2nd PD" data 1byte Data from the hour meter for the seventh latest PD 8byte 00000213 Eighth latest "1st PD" data 1byte Eighth latest "2nd PD" data 1byte Data from the hour meter for the eighth latest PD 8byte 000001A7 2Byte PDP-506PE...
Page 54
Seventh latest SD subcategory data 1byte Data from the hour meter for the seventh latest SD 8byte 00000000 Eighth latest SD data 1byte Eighth latest SD subcategory data 1byte Data from the hour meter for the eighth latest SD 8byte 00000000 2Byte PDP-506PE...
Page 55
• Number of SUS pulses : The number is calculated from data from APL and the drive sequence. The output value must be between 0174 and 2752. • APL value: The APL value for the input video signal (or mask indication) will be output in the range of 0000 to 1023. PDP-506PE...
Page 56
• Depending on the type of mask displayed, phosphor burn of the panel may occur. As the panel-protection function is forcibly turned off with this model, care must be taken when color-bar signals are to be displayed for an extended period. PDP-506PE...
Page 57
• When this command is executed, the values not stored in the EEPROM are initialized, mask indication is set to OFF, control of the power for line aging is set to OFF, and detection of the system cable is set to ON. PDP-506PE...
2 To clear the data on the pulse meter : CPM 3 To clear the data on the SD history : CSD 4 To clear the data on the PD history : CPD Using the Factory Menu See "7.1.7 HOW TO CLEAR HISTORY DATA." PDP-506PE...
POWER SUPPLY Unit 50 X DRIVE Assy 50 ADDRESS Assy 50 ADDRESS Assy 50 ADDRESS Assy 50 ADDRESS Assy HD LED Assy HD IR Assy 50 SCAN A Assy HD AUDIO Assy HD DIGITAL Assy SUS CLAMP 2 Assy PDP-506PE...
• When a shutdown occurs, a warning will be issued by the Media Receiver and displayed, then the power will be shut off. • When a shutdown or power-down occurs on the Panel side, the Media Receiver will enter Standby mode (the red LED will light). PDP-506PE...
Page 64
5 times Audio failure HD AUDIO Defective AMP IC HD AUDIO Assy IC3751 Check if the connectors are Disconnection of HD AUDIO A1 - P5 disconnected or are not connectors connected securely. PDP-506PE...
Note: With this model, the structure of Factory mode has been changed, and all items related to the Panel are gathered into PANEL FACTORY mode. Note: On-screen displays in Factory mode are indicated in white characters on a green background for the PDP-506HD/436HD and subsequent models. PDP-506PE...
Page 67
SGL MASK 01 <=> Equivalent to MKS+S01 SGL MASK 02 <=> Equivalent to MKS+S02 <=>V48<=>V50<=>V60<=>P60<=>P70<=>V72<=>V75<=> • • • • • • (Select each sequence.) 9-62 CMB MASK 08 <=> Equivalent to MKC+S08 9-63 CMB MASK 09 <=> Equivalent to MKC+S09 PDP-506PE...
Page 68
(3 bytes each) are each converted into a decimal number, and the higher-order 8 digits are displayed (that means that the lowest-order digit represents millions). • TEMP1: Indicates the temperature of the panel. By your pressing the L or R key, the temperature value can be updated. PDP-506PE...
OSD Indication OSD Indication (main) (sub) SEQUENCE PROCESSOR SQ-IC EEPROM EEPROM (IC3156) MDU-IIC MDU-IIC (with subcategory) BACKUP BACKUP (IC3754) Abnormality in RST2 RST2 DAC (IC3302 to IC3304) Panel having high temperature TEMP1 Audio IC VOL-IC (IC3158) Short-circuited speaker AUDIO PDP-506PE...
Page 70
Equivalent to RSW VOL SUS <=> 000 to 255 Equivalent to VSU VOL OFFSET <=> 000 to 255 Equivalent to VOF VOL RST P <=> 000 to 255 Equivalent to VRP SUS FREQ. <=> <=>MODE1 to MODE8<=> Equivalent to SFR PDP-506PE...
Page 71
B-HIGH <=> 000 to 511 Equivalent to PBH R-LOW <=> 000 to 999 Equivalent to PRL G-LOW <=> 000 to 999 Equivalent to PGL B-LOW <=> 000 to 999 Equivalent to PBL ABL <=> 000 to 255 Equivalent to ABL PDP-506PE...
Page 72
<SEL> : MASK ON/OFF <Lower-layer items of PANEL REVISE> Items Adjustment/Setting Value Remarks R-LEVEL <=> <=>LV-0 to LV-7<=> Equivalent to RRL G-LEVEL <=> <=>LV-0 to LV-7<=> Equivalent to RGL B-LEVEL <=> <=>LV-0 to LV-7<=> Equivalent to RBL PDP-506PE...
Page 73
• When each item is set, the process starts then the unit shifts to the upper layer. (When NO OPRT is determined, the unit will shift to the upper layer without doing anything.) • When data are set to be backed up, if the digital EEPROM has not been adjusted, do the operation of LED pattern No. 7. PDP-506PE...
Page 74
• • • CMB MASK 09 <=> Equivalent to MKC+S08 CMB MASK 10 <=> Equivalent to MKC+S09 • With the keys <LEFT> and <RIGHT>, the Panel drive sequence in the MASK indication is changed in the following way: <=>48V<=>50V<=>60V<=>72V<=>75V<=>60P<=>70P<=> PDP-506PE...
(Blue LED lit) Notes: • Although the output from XGA (43 inch) and WXGA (50 inch) can be input to the unit, this is not a mode open to general users. (With some signals, errors such as power-down may occur.) PDP-506PE...
Short-circuit the face and the reverse side, using clips, etc. Note: It is recommended to use clips like those shown here rather than alligator clips, because alligator clips may not reach the copper foil of the board. Fig. 4 Position of DRIVE OFF PDP-506PE...
Assy, perform these procedures then mount it on the product to be repaired. ETC. (+) [set] BACKUP DATA: NO OPRT ∞ (down) DIGITAL EEPROM: NO OPRT >> (right) DIGITAL EEPROM: REPAIR [set] (Press and hold for 5 seconds.) PDP-506PE...
Page 78
[set] (Press and hold for 5 seconds.) • If the HD DIGITAL Assy with which adjustment data for the main unit have been copied is mounted, the above procedures are not necessary after manual adjustment. (The indication "DIGITAL EEPROM: REPAIR" will not be displayed.) PDP-506PE...
Assys are replaced, data on various histories must be cleared. 2: To clear data using RS-232C commands, after entering Factory mode (by sending FAY or PFY), issue a corresponding command. Otherwise, the command will not be executed. PDP-506PE...
Page 80
PM/B1-BS INFO: CLEAR pulse meter [set] (Press and hold for 5 seconds.) ∞ (down) >> (right) Clearing the data on the P COUNT INFO: NO OPRT P COUNT INFO: CLEAR number of power-ons [set] (Press and hold for 5 seconds.) PDP-506PE...
Control Plate Section Remove the two screws. Remove the two screws. Remove the two hexagon head screws. Disconnect the connector. ×2 ×2 ×2 Remove the three screws. Remove the control plate. Control plate HD AUDIO Assy HD DIGITAL Assy PDP-506PE...
Page 82
2 Push the couplers of the Front Case Assy (506PE) into the rear case (506). 3 Make sure that all the couplers have been pushed into the rear case (506). Front case Assy (506PE) Front case Assy (506PE) Rear case (506) Rear case (506) Rear case (506) PDP-506PE...
Page 83
Remove the front chassis VR (50). Front chassis VR (50) Remove the two screws. Remove the two screws. Unhook the two PCB spacers. 50 X DRIVE Assy Remove the SUS CLAMP 1 and 2 Assys. SUS CLAMP 2 Assy SUS CLAMP 1 Assy PDP-506PE...
Page 84
Front chassis VL (50) Remove the four screws. Disconnect the two pin connectors. 50 Y DRIVE Assy Unhook the seven PCB spacers. Remove the 50 SCAN A and B Assys. ×2 ×2 ×2 ×2 50 SCAN B 50 SCAN A Assy Assy PDP-506PE...
Page 91
PST3610UR (HD DIGITAL ASSY : IC3304) • Reset IC Pin Arrangement (Top view) Pin Function Pin Name Pin Function Ground GND 1 Power supply / Voltage detection Capacitor connect pin for delay Reset signal output Block Diagram Electrostatic Electrostatic protection Vref protection element element PDP-506PE...
8. PANEL FACILITIES Front view 3 POWER ON indicator POWER button Remote control sensor STANDBY indicator Rear view SYSTEM CABLE WHITE BLACK SYSTEM CABLE WHITE BLACK SPEAKER (right/left) terminals SYSTEM CABLE terminal (WHITE) SYSTEM CABLE terminal (BLACK) 8 AC IN terminal PDP-506PE...