Installation 1-48

1.13.5 Grounding wire

Connect a grounding wire from one of the bolts on the scanner base, as shown
below. The crimp terminal and grounding wire are installer-supplied.
Radome
Open scanner

1.13.6 Initial start-up of radar function

Initial start-up after installation or after long storage (6 months), the scan-
ner will need an extra 20 minutes to warm up, so after Power on and going
into Standby, the radar function must be left in Standby mode for an extra 20
minutes to properly warm up the scanner. This way you will contribute to the
lifetime of the magnetron in the radar scanner.
Note: Normal start-up at regular usage will take approx. two minutes for the
scanner to warm up and be ready for transmission. For further instructions,
refer to the user manual.
Crimp terminal
Grounding wire
Ground wire
CX34/44/54-series
Chassis
Radome (bottom)
Mount base
To ship's hull
Terminal