Cabling The Exp3500 Storage Enclosure; Lc-Lc Fibre Channel Cable Lever And Latches; Removing The Lc-Lc Fibre Channel Cable From; Esm Connectors - IBM DS3500 Installation, User's, And Maintenance Manual

Ibm system storage ds3500 and exp3500 storage subsystem
Table of Contents

Advertisement

Figure 35. LC-LC Fibre Channel cable lever and latches
2. Carefully pull the connector to remove it. Ensure that you grasp the connector
Figure 36. Removing the LC-LC Fibre Channel cable from an LC-SC Fibre Channel cable
adapter
3. Replace the protective caps on the cable ends.

Cabling the EXP3500 storage enclosure

The EXP3500 storage enclosure contains an ESM that enables you to connect the
EXP3500 storage enclosure to a DS3500 storage subsystem. If you are attaching the
EXP3500 to a dual controller DS3500 storage subsystem, you must add a second
ESM to the EXP3500 storage enclosure to provide a redundant drive path.

ESM connectors

Figure 37 shows the connectors on the ESM.
SAS in connector 1
1
ESM
Figure 37. ESM connectors
SAS In 1
Lever
Latches
and not the cable when removing the LC-LC cable from the LC-SC cable
adapter as shown in Figure 36.
SAS in connector 2
SAS out connector
2
Connect a SAS cable to this connector and to either an IBM SAS controller
or the SAS Out (↓) connector of another EXP3500.
Chapter 3. Cabling the storage subsystem and storage enclosure
45