Power-Supply Switches And Connectors For Ds3500 Ac Models - IBM DS3500 Installation, User's, And Maintenance Manual

Ibm system storage ds3500 and exp3500 storage subsystem
Table of Contents

Advertisement

3. Put on anti-static protection.
4. Unpack the new power-fan controller.
a. Set the new power-fan controller on a flat, static-free surface near the
controller-drive enclosure.
b. Save all the packing materials in case you need to return the power-fan
controller.
5. Ensure that the Power switch on the new power-fan controller is turned off.
6. Check the Power-Fan Service Action Required LEDs on the controller-drive
enclosures to locate the failed power-fan controller.
Standby power LED (green)
DC power LED (green)
OK to remove LED (blue)
Fault LED (amber)
AC power LED (green)
Figure 106. AC power-supply LEDs
If a fault is detected, the amber Power-Fan Service Action Required LED is on.
If you can safely remove the power-fan controller, the blue Power-Fan Service
Action Allowed LED is on.
CAUTION:
Risk of electrical shock – Before removing or installing a power supply,
turn off the power switch, and unplug the power cord.
7. Turn off the Power switch on the power-fan controller that has failed.
Power
connector
Figure 107. Power-supply switches and connectors for DS3500 AC models
8. Remove the plastic strain relief from the power cord.
9. Unplug the power cord from the failed power-fan controller.
10. Remove the power-fan controller from the controller-drive enclosure.
a. Rotate the latches to disengage the power-fan controller.
b. Use the latches as handles to pull the power-fan controller out of the
controller-drive enclosure.
Power
Power
switch
connector
Chapter 5. Replacing components
Power
switch
143

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exp3500

Table of Contents