Download Print this page

Sanyo VPC-CG65 Service Manual page 19

Digital movie camera
Hide thumbs Also See for VPC-CG65:

Advertisement

2. AWB Adjustment
Camera
(color viewer)
Preparation:
POWER switch: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that
nothing appears in any part of the color viewer except the
white section. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Dsc Calibration
AWB Results:
1:
AGC=193,360,529,698,866
3F_AGC=0,0
WB=324,511,621
CHECK=128,128,132
WB_ND=320,511,628
CHECK_ND=128,128,134
IRIS_GAIN: 45
IRIS_OFFSET: 172
MS=1128,1526,1676,2125
IRIS=189,173,154,133,126
Fno_FOR_ISO=56
SS_FOR_ISO=1177
YLEVEL_FOR_ISO=9029
Adjustment value determination is effectuated using the "AGC",
"CHECK", "CHECK_ND", "IRIS_GAIN", "IRIS_OFFSET", "MS"
and "IRIS" values.
If AGC= a1, a2, a3, a4, a5, CHECK= wc0, wc1, wc2,
CHECK_ND= wnc0, wnc1, wnc2, MS= ms1, ms2, ms3, ms4,
IRIS= s1, s2, s3, s4, s5, IRIS_GAIN= g and IRIS_OFFSET=o
the adjustment values fulfill the conditions below, they are de-
termined as within specifications.
Pattern box
x
OK
Copy
Adjustment value determination
150<a1<450, 300<a2<600, 450<a3<750,
600<a4<900, 750<a5<1024
wc0=128 ± 2, wc1=128 ± 2, wc2=130 ± 40
wnc0=128 ± 2, wnc1=128 ± 2, wnc2=130 ± 40
801<ms1<=2500, 1201<ms2<=2900, 1251<ms3<=3100,
1401<ms4<=3600
100<=s1<=220, 100<=s2<=220, 100<=s3<=220,
100<=s4<=220, 100<=s5<=220
ms4>ms3>ms2>ms1
s1>s2>s3>s4>s5
0<=g<=255
0<=o<=255
Adjustment values other than the above are irrelevant.
3. CCD White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select "CCD Defect" on the LCD "Test", and click the "Yes".
3. After the adjustment is completed, OK will display.
4. Click the OK.
4. CCD Black Point And White Point Defect Detect
Adjustment In Lighted
Camera
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
Adjusting method:
1. Set the camera 0 cm from the pattern box. (Do not enter
any light.)
2. Double-click on the DscCalDi.exe.
3. Select "CCD Black" on the LCD "Test", and click the "Yes".
4. After the adjustment is completed, the number of defect
will appear.
– 19 –
Pattern box
(color viewer)
2
)

Advertisement

loading