HVAC SYSTEM (HEATER, VENTILATOR AND A/C)
1. General Description
A: SPECIFICATIONS
1. HEATER SYSTEM
Item
Heating capacity
Air flow rate
Max air flow rate
Heater core size
(height × length × width)
Type
Blower
Fan type and size
motor
(diameter × width)
GENERAL DESCRIPTION
Specifications
5.0 kW (4,300 kcal/h, 17,062
BTU/h) or more
3
280 m
(9,888 cu ft)/h
3
450 m
(15,892 cu ft)/h
163.9 × 200 × 25.0 mm
LHD model
(6.45 × 7.87 × 0.984 in)
181.5 × 160 × 27 mm
RHD model
(7.15 × 6.30 × 1.06 in)
Magnet motor 200 W or less
Sirocco fan type
150 × 75 mm (5.91 × 2.95 in)
• Mode selector switch: HEAT
• Temperature control switch: FULL HOT
• Temperature difference between hot water
and inlet air: 65°C (149°F)
• Hot water flow rate: 360 2 (95.1 US gal,
79.2 Imp gal)/h
Heat mode (FRESH), FULL HOT at 12.5 V
• Temperature control switch: FULL COLD
• Blower fan speed: 4th position
• Mode selector lever: RECIRC
at 12 V
AC-2
Condition