Note: if any of the original wire as
supplied with the appliance must
be replaced, it must be replaced
with type 105 °C rated wire.
ORANGE - TO VALVE
GROUND - TO VALVE
GREEN - TO VALVE
PLUG INTO 120V
EXISTING OUTLET
Figure 8.2 Fan Wiring Diagram
C. Programming the RC300 to the Control
Module
CAUTION! Risk of burns! DO NOT program the remote
control to the control module when fi replace is hot.
• Refer to the RC300 Installation Instructions included
in appliance manual bag to program the RC300 to the
control module.
20
Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14
BRACKET
WHT
NOTE: SEE FIGURE 8.1 FOR ADDITIONAL INFORMATION
WHT
BLK
GRN
GRN
BLK
BLK
FUSE WIRE
ASSEMBLY
FUSE WIRE
ASSEMBLY
BLK
BLK
GRN
GRN
BLK
BLOWERS

Hide quick links: