Installing Remote Outdoor Sensor
Install the remote outdoor sensor on a northern wall of the home, away from
direct sunlight or other heat sources that may affect its sensitivity.
IMPORTANT
The outdoor sensor must be connected with twisted pair wire
(84X49 [1000' roll] or X3790 [500' roll]). For operating a system with
®
a Humiditrol
accessory, the remote sensor MUST be installed.

Display Lights

The display lights indicate HVAC system operation.
S
HEAT or COOL light will be illuminated with a call for heating or cooling
(81M26 and 81M27 models).
S
AUX light indicates the second stage of heating − W2 is active (81M28
model only).
S
EMER light indicates that the emergency heat is enabled in HEAT/
COOL menu, regardless of heat demand (81M28 model only). Emer-
gency heat is activated via the E/W1 terminal.
S
CHECK light comes on when a 24V signal is present on the L" termi-
nal. This indicates that the equipment requires service by a qualified
technician (all models).

Memory Protection

The thermostat stores all the information concerning its programming
(state, mode, program information, last temperature measured) in a non-
volatile memory.
This function avoids the loss of the state of the thermostat when a power−
down occurs. The only thing that might be lost is the time. A super−cap pro-
vides 2 hours of power reserve (for power outages). When a power down
occurs (due to a power outage) the thermostat is able to switch off all relays.
The O and B relay will maintain their last state.
EPA ENERGYSTAR
®
EPA ENERGYSTAR
help the household save energy.
The following time and temperatures are preprogrammed into the control to
conform to Energy Star requirements.
Table 1. ENERGYSTAR
Time
Morning
Day
Evening
Night
NOTE − Humidification and dehumidification are not part of the ENERGYS-
®
TAR
program. A higher utility bill may occur when not using the setpoints
in table 1.

Resetting Program to Factory Conditions

To reset the SignatureStatt thermostat to factory conditions, press the UP
button and the LEFT button at the same time. Hold for 8 seconds. The time
of day will display 12:00 indicating a reset has occurred or until LENNOX
or the software version is shown on LCD.
NOTE − This will erase all programming and return the thermostat to the fac-
tory conditions, including the installer settings. Use this only as a last resort.
Page 21
®
Recommended Setpoints
recommended setpoints for heating and cooling can
®
Setpoints
Winter Heating
Summer Cooling
70°F (21°C)
78°F (25°C)
62°F (17°C)
85°F (29°C)
70°F (21C)
78°F (25°C)
62°F (17°C)
82°F (28°C)