Receiver Section
Item
Condition
1. Sensitivity
1) TEST CH: Low, Low', Center,
High', High (5 points)
SSG otuput : –70dBm
(70.8µV)
SSG MOD: 1.5kHz
2. Sensitivity
1) TEST CH: 2, 3
Check
SSG otuput: –115dBm
[Narrow]
(0.4µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG otuput: –117dBm
(0.32µV)
SSG MOD: 3.0kHz
3. High RSSI
1) TEST CH: Center, Low, High
[Narrow]
(3 points)
SSG otuput: –70dBm
(70.8µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG otuput: –70dBm
(70.8µV)
SSG MOD: 3.0kHz
4. Low RSSI
1) TEST CH: Center, Low, High
[Narrow]
(3 points)
SSG otuput: –118dBm
(0.28µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG otuput: –118dBm
(0.28µV)
SSG MOD: 3.0kHz
5. Open Squlch
1) TEST CH: Center, Low, High
[Narrow]
(3 points)
SSG otuput: –119dBm
(0.25µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: Center
SSG otuput: –120dBm
(0.22µV)
SSG MOD: 3.0kHz
6. Tight
1) TEST CH: Center, Low, High
Squelch
(3 points)
[Narrow]
SSG otuput: –115dBm
(0.40µV)
SSG MOD: 1.5kHz
[Wide]
2) TEST CH: 1
SSG otuput: –116dBm
(0.35µV)
SSG MOD: 3.0kHz
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
ANT
DVM
SP/MIC
Oscilloscope
connector
AF VTVM
TK-3360
Adjustment
Parts
Method
FPU
Write
Check
13dB SINAD or more
FPU
Write
Specifi cations / Remarks