Kenwood TK-3360 Service Manual page 29

Hide thumbs Also See for TK-3360:
Table of Contents

Advertisement

Common Section
Item
Condition
1. Setting
1) BATT terminal votage: 7.5V
2) SSG standard modulation
[Wide]
MOD: 1kHz, DEV: 3kHz
[Narrow]
MOD: 1kHz, DEV: 1.5kHz
2. Receive
1) CH: 3
VCO Lock
Voltage
2) CH: 2
3. Transmit
3) CH: 3
VCO Lock
PTT: ON
Voltage
3) CH: 2
PTT: ON
Transmitter Section
Item
Condition
1. Frequency
1) TEST CH: 3
PTT: ON
2. High
1) TEST CH: Low, Low', Center,
Transmit
High', High (5 points)
Power
BATT terminal voltage: 7.5V
PTT: ON
3. Low
1) TEST CH: Low, Low', Center,
Transmit
High', High (5 points)
Power
BATT terminal voltage: 7.5V
PTT: ON
4. DQT
1) TEST CH: Low, Center, High
Balance
(3 points)
[Narrow]
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT: ON
5. Maximum
1) TEST CH: Center, Low, High
Deviation
(3 points)
[Narrow]
AG: 1kHz/150mV
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
PTT: ON
[Wide]
2) TEST CH: 1
PTT: ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
TX-RX
ANT
meter
CV
DVM
Measurement
Test-
Unit
Terminal
Unit
equipment
f. counter
ANT
Power
meter
Ammeter
Power
ANT
meter
SP/MIC
Deviation
connector
meter
Oscilloscope
AG
AF VTVM
TK-3360
Adjustment
Parts
Method
FPU
4.2V±0.1V
0.6V or more
4.2V±0.1V
0.6V or more
Adjustment
Parts
Method
519.90000MHz
±50Hz
FPU
4.8W±0.1W
1.9A or less
1.0W±0.1W
0.9A or less
FPU
Adjust 2kHz
±0.5dB
deviation to be the
same as 20Hz.
2.1kHz
±100Hz
(According to
the lager +, –)
4.2kHz
±100Hz
(According to
the lager +, –)
Specifi cations / Remarks
Specifi cations / Remarks
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-3360 kTk-3360 mTk-3360 k2Tk-3360 xTk-3360 e

Table of Contents